{"product_id":"beckhoff-eri2339-0022-io-link-box","title":"BECKHOFF ERI2339-0022 IO-Link Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF ERI2339-0022 is an IO-Link box designed for decentralized industrial automation tasks in harsh field environments. Functioning as an IO-Link device supporting specification version V1.1 Class B, this module provides flexible signal extension directly on machine frames without requiring a control cabinet. It integrates digital input and output channels within a durable metal housing, connecting seamlessly to higher-level IO-Link masters via standard M12 industrial cabling.\u003c\/p\u003e\n\u003cp\u003eConstructed for demanding factory floor conditions, the unit features high environmental protection ratings and a robust zinc die-cast housing. It handles mixed signal distributions, supplying sensor power directly from internal supply rails while maintaining short-circuit protection across channels. The ERI2339-0022 streamlines machine-level wiring architectures by consolidating multiple digital signals into a single IO-Link communication line.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIO-Link V1.1 Class B communication interface via M12 A-coded plug\u003c\/li\u003e\n  \u003cli\u003eSupports 16 digital inputs or outputs configurable for diverse machine signals\u003c\/li\u003e\n  \u003cli\u003eRobust zinc die-cast housing designed for variable installation positions\u003c\/li\u003e\n  \u003cli\u003eIntegrated sensor and actuator supply sourced from P24 with total short-circuit protection\u003c\/li\u003e\n  \u003cli\u003eHigh environmental protection class for machine-level direct mounting\u003c\/li\u003e\n  \u003cli\u003eConfigurable input filter times for signal debouncing and adaptation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine control and signal acquisition without control cabinets\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly systems requiring distributed digital I\/O expansion\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor equipment with harsh environmental exposures\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery utilizing IO-Link sensor and actuator integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eERI2339-0022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eIO-Link Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003eIO-Link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpecification Version\u003c\/td\u003e\n      \u003ctd\u003eIO-Link V1.1, Class B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n      \u003ctd\u003e230.4 kbaud (COM 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e16 digital inputs or outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput\/Output Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms (default), adjustable 0 to 20 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage 0\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage 1\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 3 mA (EN 61131-2, type 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003efrom P24, max. 0.5 A, short-circuit proof in total\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eohmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel, individually short-circuit proof, sum 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003emax. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 mA from L+\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 20 mA plus load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eL+ \/ P24: yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Data\u003c\/td\u003e\n      \u003ctd\u003e16 x M8, 8 x M12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e60 mm x 126 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 450 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003eZinc die-cast\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003ctd\u003eEnsure all power supplies and field voltage sources are switched off and locked out before beginning installation or wiring work.\u003c\/td\u003e\n  \u003ctd\u003eInspect the zinc die-cast housing, M12 connectors, and seals for any transit damage or contamination.\u003c\/td\u003e\n  \u003ctd\u003eMount the module securely onto a flat machine surface using the designated fixing holes (M3 or M4 screws) in a variable installation position suited to the application.\u003c\/td\u003e\n  \u003ctd\u003eConnect the IO-Link master communication cable to the M12 A-coded interface port.\u003c\/td\u003e\n  \u003ctd\u003eAttach field sensors and actuators to the M12 input\/output connection points, ensuring correct pin assignment and torque limits.\u003c\/td\u003e\n  \u003ctd\u003eVerify that the L+ and P24 supply voltages meet the rated nominal thresholds before energizing the system.\u003c\/td\u003e\n  \u003ctd\u003ePower on the system and verify module communication status and channel LEDs during commissioning.\u003c\/td\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106468356459,"sku":"ERI2339-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/eri2339-0022-qs2javzdyiz.png?v=1776244818","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-eri2339-0022-io-link-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}