{"product_id":"beckhoff-eri2809-0022-io-link-box","title":"BECKHOFF ERI2809-0022 IO-Link Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF ERI2809-0022 is an IO-Link box designed for industrial automation environments requiring distributed signal acquisition and control. Engineered for installation directly in the field, this device functions as an IO-Link node capable of handling digital output signals while communicating via an IO-Link interface.\u003c\/p\u003e\n\u003cp\u003eThis module provides 16 digital outputs with M12 screw-type connections, supporting ohmic, inductive, and lamp loads. Operating with a nominal output voltage of 24 V DC, the unit features individually short-circuit-proof channels drawing from the P24 auxiliary supply. Housed in a robust enclosure rated for IP65, IP66, and IP67 protection, the device accommodates variable installation positions and operates reliably across demanding temperature ranges.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul style=\"margin:0.4em 0;padding-left:1.25em;\"\u003e\n\u003cli\u003eEquipped with an IO-Link V1.1 specification version supporting Class B functionality and COM 3 data transfer rates up to 230.4 kbaud.\u003c\/li\u003e\n\u003cli\u003eFeatures 16 digital outputs connected via M12 screw-type interfaces.\u003c\/li\u003e\n\u003cli\u003eDelivers a maximum output current of 0.5 A per channel, individually short-circuit proof with a total current limit of 4 A from P24.\u003c\/li\u003e\n\u003cli\u003eProvides electrical isolation between L+ and P24 supplies.\u003c\/li\u003e\n\u003cli\u003eConstructed with an IP65, IP66, and IP67 protection rating for direct machine mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul style=\"margin:0.4em 0;padding-left:1.25em;\"\u003e\n\u003cli\u003eDecentralized switching of actuators and control devices in machine building and factory automation.\u003c\/li\u003e\n\u003cli\u003eHarsh industrial environments requiring high ingress protection directly on the machine frame.\u003c\/li\u003e\n\u003cli\u003eDistributed control architectures utilizing IO-Link master communication networks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eERI2809-0022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eIO-Link Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication\u003c\/td\u003e\n      \u003ctd\u003eIO-Link\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterfaces\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, A-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e230.4 kbaud (COM 3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpecification Version\u003c\/td\u003e\n      \u003ctd\u003eIO-Link V1.1, Class B\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel from P24, individually short-circuit proof, sum 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd\u003etyp. 100 mA from L+\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 20 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eL+\/P24: yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 450 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Plug, A-coded\u003c\/td\u003e\n      \u003ctd\u003eIO-Link communication interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Screw Type Connectors\u003c\/td\u003e\n      \u003ctd\u003eDigital output signal connections\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cp\u003eEnsure the system is completely de-energized before mounting or wiring the BECKHOFF ERI2809-0022 module.\u003c\/p\u003e\n  \u003cp\u003eInspect the enclosure and M12 connectors for any physical damage or contamination.\u003c\/p\u003e\n  \u003cp\u003eMount the box securely in a variable installation position directly to the machine surface using appropriate hardware.\u003c\/p\u003e\n  \u003cp\u003eConnect the field supply, auxiliary power lines, and IO-Link communication cable observing correct pin assignments and torque limits for M12 connections.\u003c\/p\u003e\n  \u003cp\u003eVerify potential relationships and electrical isolation between L+ and P24 supplies prior to powering on the system.\u003c\/p\u003e\n  \u003cp\u003ePerform a commissioning check to confirm proper IO-Link communication and output channel functionality via the master controller.\u003c\/p\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106478317931,"sku":"ERI2809-0022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/eri2809-0022-4o0x0auar10.png?v=1776244822","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-eri2809-0022-io-link-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}