{"product_id":"beckhoff-il2302-b518-fieldbus-box-canopen-coupler-box","title":"BECKHOFF IL2302-B518 Fieldbus Box CANopen Coupler Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned to interface decentralized I\/O signals directly in the field, the \u003cstrong\u003eIL2302-B518\u003c\/strong\u003e serves as a robust \u003cstrong\u003eCANopen coupler box\u003c\/strong\u003e within the Beckhoff Fieldbus Box system. This module provides direct connection of IP-Link extension modules to a CANopen network, offering a highly efficient solution for distributing digital and analog signals without requiring a protective control cabinet.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eIL2302-B518\u003c\/strong\u003e coordinates the transfer of decentralized process data from up to 120 extension modules to the higher-level controller. By integrating the fieldbus interface, power supply connections, and IP-Link communication into a single compact housing, this module minimizes installation complexity and space requirements in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSupports connection of up to 120 IP-Link extension modules.\u003c\/li\u003e\n  \u003cli\u003eHandles a maximum of 128 bytes of input data and 128 bytes of output data.\u003c\/li\u003e\n  \u003cli\u003eIntegrated T-connector for seamless CANopen network routing.\u003c\/li\u003e\n  \u003cli\u003eAutomatic detection of data transfer rates from 10 kbaud up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eComprehensive CANopen feature support including Node Guarding, Life Guarding, and Emergency Objects.\u003c\/li\u003e\n  \u003cli\u003eConfigurable via the KS2000 software tool or through standard Service Data Objects (SDOs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy industrial machinery and manufacturing lines.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging and food processing equipment.\u003c\/li\u003e\n  \u003cli\u003eDecentralized control installations in washdown or high-dust zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eIL2302-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProduct Type\u003c\/strong\u003e\n      \u003ctd\u003eCANopen Coupler Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtocol\u003c\/strong\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of Extension Modules\u003c\/strong\u003e\n      \u003ctd\u003eMax. 120 (max. 128 byte input \/ 128 byte output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eDigital Signal Capacity\u003c\/strong\u003e\n      \u003ctd\u003eMax. 960 inputs and 960 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eAnalog Signal Capacity\u003c\/strong\u003e\n      \u003ctd\u003eMax. 60 inputs and 60 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eNumber of PDOs\u003c\/strong\u003e\n      \u003ctd\u003e16 send and 16 receive process data objects\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\n      \u003ctd\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\n      \u003ctd\u003e45 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\n      \u003ctd\u003e500 V (Control voltage \/ fieldbus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Rating\u003c\/strong\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector Description\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBus Interface (Input)\u003c\/strong\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eCANopen incoming bus connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBus Interface (Output)\u003c\/strong\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eCANopen outgoing bus connection (integrated T-connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Feed\u003c\/strong\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eControl voltage and sensor power feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Downstream\u003c\/strong\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower distribution to downstream modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the unit is securely mounted to a flat surface using the integrated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eTo maintain the IP67 protection rating, all unused M8 and M12 connection ports must be sealed with appropriate protective caps.\u003c\/li\u003e\n  \u003cli\u003eVerify that the control voltage is stable at 24 V DC before powering the network.\u003c\/li\u003e\n  \u003cli\u003eKeep bus cables isolated from high-voltage AC cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106456396139,"sku":"IL2302-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/il2302-b518-dhgr3mzuwsy.png?v=1776244851","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-il2302-b518-fieldbus-box-canopen-coupler-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}