{"product_id":"beckhoff-ip1001-b510-canopen-fieldbus-box","title":"BECKHOFF IP1001-B510 CANopen Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1001-B510\u003c\/strong\u003e is a high-performance CANopen Fieldbus Box designed for decentralised digital signal acquisition directly on machinery. This unit integrates eight digital input channels, each featuring a 3 ms filter, with a direct CANopen bus interface. By placing the I\/O interface directly at the machine site, it eliminates the need for a separate protective terminal enclosure and complex wiring setups.\u003c\/p\u003e\n\u003cp\u003eWith its robust design, the \u003cstrong\u003eBECKHOFF IP1001-B510\u003c\/strong\u003e manages high-speed binary input communications for standard industrial sensors. The unit's electronics are shielded from environmental factors and provide complete physical separation between the fieldbus and control voltage potentials to prevent signal interference.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with 8 digital inputs, operating at 24 V DC with a 3 ms input filter time.\u003c\/li\u003e\n  \u003cli\u003eDirect CANopen network integration via a standard 5-pin M12 bus interface.\u003c\/li\u003e\n  \u003cli\u003eAutomatic baud rate detection spanning from 10 kbaud up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eComprehensive CANopen feature support including life guarding, node guarding, emergency object handling, and variable mapping.\u003c\/li\u003e\n  \u003cli\u003eDual configuration paths via the KS2000 commissioning software or through service data objects (SDOs).\u003c\/li\u003e\n  \u003cli\u003eCertified IP65, IP66, and IP67 ingress protection for direct placement in harsh conditions.\u003c\/li\u003e\n  \u003cli\u003eCompact M8 connectors for control voltage power feed and downstream distribution loop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralised machine monitoring and control systems without control cabinet requirements.\u003c\/li\u003e\n  \u003cli\u003eIndustrial assembly, conveyor lines, and automated packaging systems.\u003c\/li\u003e\n  \u003cli\u003eDirect integration of binary proximity sensors and limit switches in wet or dusty processing areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1001-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals and Markings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Signal Details\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDigital, 24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current consumption (maximum 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; control voltage\/inputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Interface Properties\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection from 10 kbaud up to 1 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcess Data Objects (PDOs)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive PDOs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 configuration software or controller (service data objects)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Feed Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Downstream Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the hardware model number matches the system architecture documentation prior to installation.\u003c\/li\u003e\n  \u003cli\u003eIsolate and lock out all power sources before proceeding with physical mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely using the integrated mounting holes on the housing body. Ensure the unit has clean physical placement.\u003c\/li\u003e\n  \u003cli\u003eConnect the CANopen fieldbus cable to the 5-pin M12 connector, ensuring correct thread alignment to preserve the IP rating.\u003c\/li\u003e\n  \u003cli\u003eConnect physical sensor leads to the M8 digital input ports. Take care to align the keys properly before tightening the retention rings.\u003c\/li\u003e\n  \u003cli\u003eRoute and connect the 24 V DC control voltage line to the 4-pin M8 male socket. Connect the downstream power cable to the next device if daisy-chaining.\u003c\/li\u003e\n  \u003cli\u003eRestore power and configure the node parameter details in the controller application or with the KS2000 program.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a legacy unit, ensure that all electrical supplies to the \u003cstrong\u003eBECKHOFF IP1001-B510\u003c\/strong\u003e are fully shut down. Document the physical M8 and M12 port mappings before physical disassembly. Verify that the matching CANopen baud rate and node parameters are applied to the replacement module to guarantee restoration of correct network communications.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106485985643,"sku":"IP1001-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1001-b510-h4afr3ji2ut.png?v=1776244866","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1001-b510-canopen-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}