{"product_id":"beckhoff-ip1002-b318-profibus-fieldbus-box","title":"BECKHOFF IP1002-B318 PROFIBUS Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1002-B318\u003c\/strong\u003e is an IP67-rated decentralized Fieldbus Box module designed to transition 8 digital input signals directly from the field to a PROFIBUS DP network. Built for control-cabinet-free applications, this module facilitates direct machine mounting, reducing installation costs and simplifying field wiring. The module features an integrated T-connector for its PROFIBUS DP interfaces, permitting direct loop-through connection of the bus line without additional external accessories.\u003c\/p\u003e\n\n\u003cp\u003eSuitable for demanding industrial operations, the \u003cstrong\u003eBECKHOFF IP1002-B318\u003c\/strong\u003e is enclosed in a durable polyamide housing that provides exceptional protection against dust, water, and mechanical stress. With standard M12 sensor connections and a 3.0 ms input filter, it guarantees reliable signal transmission in challenging physical environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital inputs for standard 24 V DC sensors\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud\u003c\/li\u003e\n  \u003cli\u003eIntegrated M12 T-connector layout (1 x plug, 1 x socket, B-coded) for simple bus loop-through\u003c\/li\u003e\n  \u003cli\u003eM12 screw-type connections for reliable sensor signal transmission\u003c\/li\u003e\n  \u003cli\u003eM8 power supply ports with feed and downstream loop-through capability\u003c\/li\u003e\n  \u003cli\u003eShort-circuit-proof sensor supply from the control voltage (maximum 0.5 A total)\u003c\/li\u003e\n  \u003cli\u003eIP65\/66\/67 ingress protection for cabinet-free field deployment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized input acquisition on automated assembly lines\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems with distributed I\/O requirements\u003c\/li\u003e\n  \u003cli\u003ePackaging machines and processing units operating in wet or dusty environments\u003c\/li\u003e\n  \u003cli\u003eDistributed PROFIBUS DP network installations demanding compact, local sensor integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP1002-B318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Size\u003c\/td\u003e\n      \u003ctd\u003eXXL housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes (3.5 mm diameter) for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\/Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003eTyp. 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePROFIBUS and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Options\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 or the controller (DP-V1 extensions supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current (max. 0.5 A total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eChannels to control voltage: No; Channels to channels: No; Control voltage to fieldbus: Depends on bus system\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface or Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Input Channels\u003c\/td\u003e\n      \u003ctd\u003e8 x screw-type sockets for digital sensor connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 PROFIBUS Socket\u003c\/td\u003e\n      \u003ctd\u003e5-pin B-coded connection for incoming bus line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 PROFIBUS Plug\u003c\/td\u003e\n      \u003ctd\u003e5-pin B-coded connection for outgoing bus line (loop-through)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Power Feed\u003c\/td\u003e\n      \u003ctd\u003e4-pin male connector for 24 V DC control\/load voltage supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Power Downstream\u003c\/td\u003e\n      \u003ctd\u003e4-pin female connector for loop-through supply to next module\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the BECKHOFF IP1002-B318 is correct for your system design and network configuration before mounting.\u003c\/li\u003e\n  \u003cli\u003eEnsure that all relevant electrical supplies and fieldbus lines are completely de-energized.\u003c\/li\u003e\n  \u003cli\u003eMount the module directly onto a flat mounting surface using the 2 fixing holes (3.5 mm diameter) and appropriate M3 screws.\u003c\/li\u003e\n  \u003cli\u003eInspect all M12 and M8 connection points for contamination or physical damage before attaching cables.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming and outgoing PROFIBUS cables to the B-coded M12 connections, checking for secure alignment.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC power supply to the M8 power feed connector, and utilize the downstream M8 connection for daisy-chaining if required.\u003c\/li\u003e\n  \u003cli\u003eSecurely tighten all M12 sensor cables and dummy plugs to maintain the IP65\/66\/67 physical rating.\u003c\/li\u003e\n  \u003cli\u003eConfigure and commission the node inside your PROFIBUS DP master environment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106475565419,"sku":"IP1002-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b318-sxzq4hwfbwt.png?v=1776244870","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1002-b318-profibus-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}