{"product_id":"beckhoff-ip1002-b518-fieldbus-box-8-channel-digital-input-module","title":"Beckhoff IP1002-B518 Fieldbus Box 8-Channel Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized acquisition of digital signals, the \u003cstrong\u003eBeckhoff IP1002-B518\u003c\/strong\u003e Fieldbus Box operates as an 8-channel digital input module communicating via the CANopen protocol. This ruggedized, IP67-rated device interfaces directly with physical sensors in the field, eliminating the need for protective control cabinets and reducing wiring complexity. The module features an integrated M12 T-connector for seamless CANopen bus routing, alongside standard M8 connections for electrical power supply feed and downstream distribution.\u003c\/p\u003e\n\n\u003cp\u003eEquipped with a 3.0 ms input filter, the \u003cstrong\u003eIP1002-B518\u003c\/strong\u003e digital input module guarantees reliable signal acquisition from proximity switches, limit switches, and photoelectric sensors in high-noise industrial environments. The system supports automatic baud rate detection from 10 kbaud up to 1 Mbaud, enabling straightforward integration into existing CANopen industrial networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital input channels with a standard 3.0 ms filter delay.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CANopen interface supporting up to 16 send and 16 receive Process Data Objects (PDOs).\u003c\/li\u003e\n  \u003cli\u003eDual M12 fieldbus connections (1 x plug, 1 x socket) with integrated T-connector functionality for daisy-chain networks.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof sensor supply sourced directly from the control voltage (maximum 0.5 A total).\u003c\/li\u003e\n  \u003cli\u003eDiagnostic capabilities including life guarding, node guarding, emergency objects, and variable mapping.\u003c\/li\u003e\n  \u003cli\u003eRobust polyamide housing with high resistance to vibration, shock, and electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed machinery control and conveyor automation systems.\u003c\/li\u003e\n  \u003cli\u003eProcess manufacturing lines requiring machine-mount, cabinet-free I\/O architecture.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling plants utilizing CANopen network structures.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines and heavy-duty robotic workstations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1002-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (IPxxxx-B51x series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Delay\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"0\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"1\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin), integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption (Box)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyamide PA6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnector Style\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus In\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 Plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eCANopen bus entry point\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Out\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 Socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eDownstream CANopen connection (T-connector branch)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 Male, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control voltage input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 Female, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eLoop-through 24 V DC control voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs 1-8\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12, screw-type\u003c\/td\u003e\n      \u003ctd\u003eSensor connection terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSecurely mount the Fieldbus Box using the two integrated 3.5 mm mounting holes designed for M3 screws.\u003c\/li\u003e\n  \u003cli\u003eTo maintain IP67 environmental sealing, ensure all unused M12 and M8 ports are sealed with appropriate industrial protective caps.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the cumulative 0.5 A current limit on the sensor power supply.\u003c\/li\u003e\n  \u003cli\u003eVerify that the CANopen network termination is correctly applied at both physical ends of the communication line.\u003c\/li\u003e\n  \u003cli\u003eKeep power cabling and high-voltage transmission lines separated from the fieldbus signal line to limit electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE\u003c\/strong\u003e: Conforms to European Union standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL\u003c\/strong\u003e: Underwriters Laboratories listed.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC Standards\u003c\/strong\u003e: Conforms to EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Testing\u003c\/strong\u003e: Conforms to EN 60068-2-6 (Vibration) and EN 60068-2-27 (Shock).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106463015275,"sku":"IP1002-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1002-b518-2lykppotk05.png?v=1776244873","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1002-b518-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}