{"product_id":"beckhoff-ip1010-b200-lightbus-fieldbus-box","title":"BECKHOFF IP1010-B200 Lightbus Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1010-B200\u003c\/strong\u003e is an 8-channel digital input Fieldbus Box designed for decentralized automation tasks in rugged industrial environments. It serves as a reliable link between binary sensors and the Lightbus fiber-optic fieldbus system, allowing digital signals to be captured directly at the machine level without requiring a protective control cabinet.\u003c\/p\u003e\n\n\u003cp\u003eConstructed with a highly durable PA6 polyamide enclosure, this module offers robust IP65\/66\/67 protection against moisture, dust, and mechanical stress. It features 8 mm snap-type connection technology for fast, tool-free sensor integration and incorporates an integrated 0.2 ms input filter to ensure stable signal processing in high-speed applications.\u003c\/p\u003e\n\n\u003cp\u003eThe fieldbus connection is established via high-speed Lightbus fiber-optic interfaces, operating at up to 2.5 Mbaud. This fiber-optic medium provides excellent noise immunity and complete electrical isolation, making the module ideal for environments with severe electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital input channels with a nominal operating voltage of 24 V DC.\u003c\/li\u003e\n  \u003cli\u003eFast-response input filter of 0.2 ms for rapid signal transitions.\u003c\/li\u003e\n  \u003cli\u003eLightbus fiber-optic interface supporting data transfer rates of 2.5 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eRugged polyamide PA6 housing featuring IP65, IP66, and IP67 ratings.\u003c\/li\u003e\n  \u003cli\u003e8 mm snap-type sockets for quick and vibration-resistant sensor connections.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof sensor supply (up to 0.5 A total) derived from the control voltage.\u003c\/li\u003e\n  \u003cli\u003eM8 4-pin power connection layout with upstream feed-through capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine mounting and tool-head control systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveying, and sorting systems where field cabinets are impractical.\u003c\/li\u003e\n  \u003cli\u003eHigh-EMI manufacturing zones requiring optical fiber signal isolation.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines and packaging machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1010-B200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, Type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, Type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003eTypically 6 mA (EN 61131-2, Type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Delay\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Sockets\u003c\/td\u003e\n      \u003ctd\u003e8 mm snap-type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eLightbus and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n      \u003ctd\u003e2.5 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eAPF (plastic) fiber-optic conductor (1,000 um)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Station Distance\u003c\/td\u003e\n      \u003ctd\u003e45 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x fiber-optic socket for plug ZS1020-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003ePower Supply\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Interface\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage to fieldbus: Yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 250 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Method\u003c\/td\u003e\n      \u003ctd\u003e2 x 3.5 mm diameter fixing holes for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\/Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e8 mm Snap Sockets (1 to 8)\u003c\/td\u003e\n      \u003ctd\u003eDigital Input Channels 1 through 8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eIncoming 24 V DC Control Voltage Feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eDownstream 24 V DC Power Supply Loop-through\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFiber-Optic Sockets\u003c\/td\u003e\n      \u003ctd\u003eLightbus Incoming and Outgoing optical rings\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power supplies are de-energized before mounting, wiring, or servicing the unit.\u003c\/li\u003e\n  \u003cli\u003eSecure the Fieldbus Box using the two 3.5 mm mounting holes with M3 fasteners. Ensure the mounting surface is flat to avoid mechanical stress on the housing.\u003c\/li\u003e\n  \u003cli\u003eVerify the maximum permissible bending radius for the fiber-optic cables during routing to prevent attenuation and transmission failures.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming 24 V DC control voltage to the M8 male connector. If daisy-chaining, connect downstream modules to the M8 female connector.\u003c\/li\u003e\n  \u003cli\u003eInstall the 8 mm snap-type sensor connections, verifying that the sensors operate within the matching 24 V DC signal parameters.\u003c\/li\u003e\n  \u003cli\u003ePower up the control supply and verify system communication status via the controller interface.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eShut down and lock out the primary 24 V DC control voltage feeding the station.\u003c\/li\u003e\n  \u003cli\u003eDisconnect the fiber-optic cables carefully, protecting the optical terminals from dust, debris, and oil contaminants.\u003c\/li\u003e\n  \u003cli\u003eUnplug all 8 mm snap-type input sensors and label each corresponding channel position to prevent rewiring errors.\u003c\/li\u003e\n  \u003cli\u003eRemove the M8 power cables and unscrew the mounting fasteners to detach the old module.\u003c\/li\u003e\n  \u003cli\u003eMount the replacement module, secure all connections as previously mapped, and run initial physical checks before re-energizing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106513215851,"sku":"IP1010-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1010-b200-pgzku4otfly.png?v=1776244877","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1010-b200-lightbus-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}