{"product_id":"beckhoff-ip1010-b520-fieldbus-box","title":"BECKHOFF IP1010-B520 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1010-B520\u003c\/strong\u003e is an IP67-rated Fieldbus Box designed for decentralized signal acquisition directly on machinery, eliminating the need for protective control cabinets. This robust module combines a high-performance DeviceNet fieldbus interface with 8 digital input channels in a compact and durable housing.\u003c\/p\u003e\n\u003cp\u003eEquipped with a fast 0.2 ms input filter, the \u003cstrong\u003eBECKHOFF IP1010-B520\u003c\/strong\u003e is engineered for applications requiring rapid and precise signal detection. It utilizes Ø8 mm snap-in connectors to establish quick, toolless, and secure connections with sensors in demanding industrial environments where moisture, dust, and mechanical stress are common.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated DeviceNet network interface (-B520) for seamless control system integration\u003c\/li\u003e\n  \u003cli\u003e8 digital input channels for 24 V DC signals\u003c\/li\u003e\n  \u003cli\u003eFast 0.2 ms input filter limit for high-speed sensor signal acquisition\u003c\/li\u003e\n  \u003cli\u003eØ8 mm snap-in connection technology (3-pin) for rapid field wiring\u003c\/li\u003e\n  \u003cli\u003eRobust IP67 protection rating for cabinet-free installation directly on equipment\u003c\/li\u003e\n  \u003cli\u003eCompact, space-saving design suitable for tight mounting footprints\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized input monitoring in machine construction and assembly lines\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation networks utilizing DeviceNet communication structures\u003c\/li\u003e\n  \u003cli\u003eApplications requiring rapid signal response times such as limit switches and sensor arrays\u003c\/li\u003e\n  \u003cli\u003eHarsh environments subject to dust, water splashes, and physical vibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1010-B520\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Coupler Box)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003e8 x Ø8 mm snap-in connectors, 3-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed-in via M8 connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviceNet Interface\u003c\/td\u003e\n      \u003ctd\u003eFieldbus communication connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs (1 to 8)\u003c\/td\u003e\n      \u003ctd\u003eØ8 mm snap-in connectors for 24 V DC sensor signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eControl and load voltage supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire automation system is powered down and de-energized before mounting the module.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the Fieldbus Box to a flat, vibration-resistant surface using the integrated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eConnect the DeviceNet communication line to the designated interface, verifying that connectors are tightened to ensure sealing.\u003c\/li\u003e\n  \u003cli\u003ePlug the 24 V DC power supply cabling into the feed-in port.\u003c\/li\u003e\n  \u003cli\u003eConnect the sensors using compatible Ø8 mm 3-pin snap-in cables, pushing them in firmly until locked.\u003c\/li\u003e\n  \u003cli\u003eSeal any unused sensor connections with protective IP67-rated caps to prevent ingress of dust or moisture.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106492408171,"sku":"IP1010-B520","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1010-b520-vap5bgk2isi.png?v=1776244881","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1010-b520-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}