{"product_id":"beckhoff-ip1010-b528-devicenet-fieldbus-box","title":"BECKHOFF IP1010-B528 DeviceNet Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP1010-B528 is a distributed Fieldbus Box designed for digital input acquisition directly within industrial field environments. Equipped with 8 digital input channels, this module captures binary control signals from sensors and transmits them to a centralized automation system. Built to operate on a DeviceNet network, it ensures dependable data exchange in harsh or space-constrained locations.\u003c\/p\u003e\n\n\u003cp\u003eThis compact device features 8 mm snap-type (Ø8) connectors for efficient, tool-free connection of sensor lines. To streamline network topology, the BECKHOFF IP1010-B528 incorporates an integrated M12 T-connector interface. This architecture allows the DeviceNet fieldbus line to be looped directly from one station to the next without requiring external active distribution modules or separate T-pieces.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for decentralized mounting without a protective control cabinet, the module has a fully sealed polyamide housing. It is designed to withstand mechanical vibrations, high moisture, and dust, making it suitable for distributed machine architectures where direct-to-machine installation is required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital input channels with a standard 0.2 ms input filter\u003c\/li\u003e\n  \u003cli\u003eIntegrated DeviceNet interface supporting automatic baud rate detection up to 500 kbaud\u003c\/li\u003e\n  \u003cli\u003eBuilt-in T-connector using 5-pin M12 connections (one plug, one socket)\u003c\/li\u003e\n  \u003cli\u003eSpace-saving 8 mm snap-type input connection points\u003c\/li\u003e\n  \u003cli\u003eProtection rating of IP65, IP66, and IP67 for direct environmental exposure\u003c\/li\u003e\n  \u003cli\u003eComprehensive local LED diagnostics for channel states and bus status\u003c\/li\u003e\n  \u003cli\u003eMechanically stable polyamide construction with integrated mounting holes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized sensor signal acquisition on automated production lines\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems, sortation systems, and conveyor lines\u003c\/li\u003e\n  \u003cli\u003eMachine tool and packaging machinery automation assemblies\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O setups in DeviceNet-controlled plant networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eSystem and Network Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eDigital Input Parameters\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connection Technology\u003c\/td\u003e\n      \u003ctd\u003e8 mm snap-type socket (Ø8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003eTypically 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eDerived from control voltage, maximum 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eElectrical and Auxiliary Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors (maximum 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage to fieldbus: 500 V; Channels to control voltage: none\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eMechanical and Environmental\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePolyamide (PA6)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting Method\u003c\/td\u003e\n      \u003ctd\u003e2 x fixing holes (3.5 mm diameter) for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, and IP67 (conforming to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 and EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eFunction and Pin Mapping\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviceNet Connection (M12)\u003c\/td\u003e\n      \u003ctd\u003e5-pin plug and socket with integrated T-piece for bus continuation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs (Ø8 mm Sockets)\u003c\/td\u003e\n      \u003ctd\u003e8 separate snap-in connection points for 24 V DC digital sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply (M8)\u003c\/td\u003e\n      \u003ctd\u003e4-pin male input feed and 4-pin female downstream feed for power pass-through\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the power supply is completely disconnected and locked out before starting any mechanical installation or wiring.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely using the two integrated 3.5 mm mounting holes and suitable M3 screws, ensuring the mounting surface is flat to avoid stress on the housing.\u003c\/li\u003e\n  \u003cli\u003eConnect the DeviceNet communication cables using the built-in M12 plug and socket connections. Tighten the collar nuts to ensure an IP-rated seal.\u003c\/li\u003e\n  \u003cli\u003eWire the 24 V DC control supply to the M8 power feed connector, and daisy-chain to neighboring modules using the downstream M8 socket if required.\u003c\/li\u003e\n  \u003cli\u003eInsert the sensor connections into the designated 8 mm snap-type sockets until they engage firmly. Verify that the cable seals are properly seated.\u003c\/li\u003e\n  \u003cli\u003eCheck local status LEDs upon powering up the system to verify appropriate fieldbus communication and channel states.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106453512555,"sku":"IP1010-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1010-b528-ri3buwkkv4r.png?v=1776244884","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1010-b528-devicenet-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}