{"product_id":"beckhoff-ip1011-b318-fieldbus-box","title":"BECKHOFF IP1011-B318 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1011-B318\u003c\/strong\u003e is a digital input Fieldbus Box designed for decentralized industrial automation applications. As part of the IP1011 product series, this module provides direct connection for digital sensor signals in harsh environments without requiring a control cabinet. It communicates via the PROFIBUS protocol and features an integrated T-connector for straightforward bus and power daisy-chaining.\u003c\/p\u003e\n\u003cp\u003eEquipped with 8 digital input channels operating at a nominal 24 V DC, the device processes binary control signals from sensors such as proximity switches, optical sensors, or mechanical limit switches. The rugged IP67-rated housing protects internal electronics against dust, moisture, and mechanical stress, making it suitable for direct machine-level mounting in factory automation lines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePROFIBUS communication interface for decentralized network integration\u003c\/li\u003e\n  \u003cli\u003e8 digital input channels for 24 V DC sensor signals\u003c\/li\u003e\n  \u003cli\u003eM8 connector technology for sensor and actuator interfacing\u003c\/li\u003e\n  \u003cli\u003eIntegrated T-connector for bus and power distribution without external splitters\u003c\/li\u003e\n  \u003cli\u003eRugged IP67 housing designed for direct machine mounting without control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized signal acquisition in factory automation and assembly lines\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor system monitoring\u003c\/li\u003e\n  \u003cli\u003eMachine tool and packaging equipment sensor integration\u003c\/li\u003e\n  \u003cli\u003eIndustrial environments requiring cabinet-free IP67 I\/O architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP1011-B318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e8 digital inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnections\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Connection\u003c\/td\u003e\n      \u003ctd\u003eM8 connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Connection\u003c\/td\u003e\n      \u003ctd\u003eIntegrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is fully de-energized before mounting or wiring the BECKHOFF IP1011-B318 Fieldbus Box.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely to a flat machine surface using appropriate mechanical fasteners through the provided mounting holes.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS communication line and power supply using the integrated T-connector interface.\u003c\/li\u003e\n  \u003cli\u003eAttach field sensors to the M8 input connectors, ensuring correct pin assignment for the 24 V DC signals.\u003c\/li\u003e\n  \u003cli\u003eVerify all cable connections, shield integrity, and potential distribution before restoring power to the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106467832171,"sku":"IP1011-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1011-b318-1rvb02evup5.png?v=1776244888","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1011-b318-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}