{"product_id":"beckhoff-ip1011-b510-canopen-fieldbus-box","title":"BECKHOFF IP1011-B510 CANopen Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1011-B510\u003c\/strong\u003e is a high-performance, decentralized CANopen Fieldbus Box designed for acquiring digital signals directly in the field. Equipped with 8 digital inputs, this unit allows direct on-machine installation without the need for a protective control cabinet, minimizing wiring effort and maximizing installation flexibility in demanding industrial environments.\u003c\/p\u003e\n\n\u003cp\u003eOperating with a fast 0.2 ms input filter, the \u003cstrong\u003eBECKHOFF IP1011-B510\u003c\/strong\u003e ensures reliable high-speed signal capture conforming to EN 61131-2 (type 2) standards. The physical signal connection is made via space-saving, screw-type M8 interfaces, while fieldbus communication runs over a standardized CANopen interface. The compact polyamide housing features robust IP65, IP66, and IP67 protection ratings, shielding the internal components from water, dust, and mechanical stress.\u003c\/p\u003e\n\n\u003cp\u003eTo simplify network design, the box automatically detects baud rates from 10 kbaud up to 1 Mbaud and features an integrated 500 V electrical isolation barrier between the control voltage and the fieldbus network. Configuration can be managed through the KS2000 software tool or directly via the system controller using Service Data Objects (SDOs).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital input channels for standard 24 V DC sensors.\u003c\/li\u003e\n  \u003cli\u003eFast 0.2 ms input filter for quick, reliable signal processing.\u003c\/li\u003e\n  \u003cli\u003eCANopen fieldbus connection with automatic baud rate detection from 10 kbaud up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eM8 screw-type connection points for secure sensor connection.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit-proof sensor supply of up to 0.5 A total from control voltage.\u003c\/li\u003e\n  \u003cli\u003eIntegrated electrical isolation of 500 V between control voltage and the fieldbus network.\u003c\/li\u003e\n  \u003cli\u003eHigh-density IP65, IP66, and IP67 protection for direct machine mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized digital sensor signal acquisition in mechanical engineering.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control networks using CANopen.\u003c\/li\u003e\n  \u003cli\u003eOn-machine installation in environments with high moisture or dust levels.\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O systems requiring reliable, cabinet-free signal integration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1011-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes (3.5 mm diameter) for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connections\u003c\/td\u003e\n      \u003ctd\u003eM8, screw-type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; control voltage\/inputs: no\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Feed Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Downstream Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCANopen and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBaud Rates\u003c\/td\u003e\n      \u003ctd\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of PDOs\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive process data objects\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional Features\u003c\/td\u003e\n      \u003ctd\u003eLife guarding, node guarding, emergency object, variable mapping, store\/restore\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software tool or the controller (SDOs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Bus Interface (5-pin)\u003c\/td\u003e\n      \u003ctd\u003eCANopen fieldbus communication connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eMain 24 V DC control voltage input feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Socket (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eDownstream 24 V DC supply loop connection to subsequent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Screw Sockets (8 points)\u003c\/td\u003e\n      \u003ctd\u003eIndividual connections for 24 V DC digital input signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDe-energize the System:\u003c\/strong\u003e Turn off all control voltage and fieldbus power lines prior to mechanical or electrical installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Securely mount the polyamide housing to a flat surface using the two integrated 3.5 mm diameter fixing holes with suitable M3 screws. Do not overtighten.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFieldbus Wiring:\u003c\/strong\u003e Connect the CANopen fieldbus cable to the 5-pin M12 interface, ensuring correct pinning and shielding parameters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Setup:\u003c\/strong\u003e Connect the 24 V DC control voltage line to the 4-pin M8 male socket. If daisy-chaining modules, route the downstream power from the 4-pin M8 female socket to the next device.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor Connections:\u003c\/strong\u003e Wire the digital sensors to the M8 screw-type input sockets. Ensure correct connection to prevent short circuits, checking that the total sensor load does not exceed 0.5 A.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Verification:\u003c\/strong\u003e Restore power and monitor the integrated diagnostic LEDs to verify proper CANopen initialization and correct input status changes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMarking\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCE\u003c\/td\u003e\n      \u003ctd\u003eConforms to European EMC and low-voltage standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUL\u003c\/td\u003e\n      \u003ctd\u003eUnderwriters Laboratories certification for US\/Canada safety standards\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106498175339,"sku":"IP1011-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1011-b510-0r153o0h3wa.png?v=1776244888","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1011-b510-canopen-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}