{"product_id":"beckhoff-ip1012-b318-fieldbus-box","title":"BECKHOFF IP1012-B318 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP1012-B318\u003c\/strong\u003e is a high-performance Fieldbus Box designed for decentralized automation environments. Acting as an 8-channel digital input module, this device allows the direct connection of 24 V DC sensors to a PROFIBUS DP network. It is housed in a rugged XXL polyamide enclosure, enabling direct mounting on machinery and equipment without requiring a protective control cabinet.\u003c\/p\u003e\n\n\u003cp\u003eTo simplify field wiring, the \u003cstrong\u003eBECKHOFF IP1012-B318\u003c\/strong\u003e features an integrated M12 T-connector for the PROFIBUS interface, allowing direct loop-through of the fieldbus line. With an input filter time of 0.2 ms, this module ensures high-speed and accurate transmission of digital signals, making it ideal for distributed control systems requiring rapid signal acquisition and high mechanical endurance.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital inputs for standard 24 V DC sensors.\u003c\/li\u003e\n  \u003cli\u003eFast 0.2 ms input filter for rapid digital signal processing.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface with automatic baud rate detection up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in T-connector (1 x M12 plug, 1 x M12 socket) for simplified bus daisy-chaining.\u003c\/li\u003e\n  \u003cli\u003eM12 screw-type input connectors for secure, vibration-resistant sensor wiring.\u003c\/li\u003e\n  \u003cli\u003eIntegrated short-circuit proof sensor supply up to a maximum of 0.5 A.\u003c\/li\u003e\n  \u003cli\u003eM8 power supply connections for feed and downstream distribution.\u003c\/li\u003e\n  \u003cli\u003eRugged polyamide (PA6) housing with an IP65\/66\/67 protection rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized digital input acquisition on automated assembly lines.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and material handling systems requiring direct-mount I\/O.\u003c\/li\u003e\n  \u003cli\u003eWet or dusty industrial environments demanding high-ingress-protection modules.\u003c\/li\u003e\n  \u003cli\u003ePROFIBUS DP installations requiring simplified bus routing without external T-pieces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003e\u003ch4\u003eGeneral Specifications\u003c\/h4\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP1012-B318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Size\u003c\/td\u003e\n      \u003ctd\u003eXXL housing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes, 3.5 mm diameter (for M3 screws)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003e\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Current\u003c\/td\u003e\n      \u003ctd\u003etyp. 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003e\u003ch4\u003ePROFIBUS and Communication\u003c\/h4\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded, integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Options\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software or the master controller (DP-V1 extensions supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003e\u003ch4\u003eElectrical and Power Supply\u003c\/h4\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current (max. 0.5 A total)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No; Control voltage\/inputs: According to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003e\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Inputs (Channels 1–8)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 x screw-type connectors for 24 V DC digital sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePROFIBUS M12 Plug (5-pin)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eB-coded fieldbus incoming connection with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePROFIBUS M12 Socket (5-pin)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eB-coded fieldbus outgoing connection with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Inlet (4-pin Male)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC feed connection for control voltage and sensor supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Outlet (4-pin Female)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC downstream connection to chain power to neighboring modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the \u003cstrong\u003eBECKHOFF IP1012-B318\u003c\/strong\u003e module is compatible with your active PROFIBUS DP network configuration.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies are de-energized before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eMount the module directly to the machine structure using the two 3.5 mm fixing holes for M3 screws.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS DP cable to the integrated M12 T-connector ports. Use B-coded M12 connectors only.\u003c\/li\u003e\n  \u003cli\u003eConnect the digital sensor cables to the designated M12 screw-type channels, ensuring proper pin assignment and tightening to preserve the ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC feed supply to the 4-pin M8 male connector. If needed, loop the power to the next module using the 4-pin M8 female downstream connector.\u003c\/li\u003e\n  \u003cli\u003eVerify all connected ports are fully sealed with protective caps on unused channels to maintain the IP65\/66\/67 rating before restoring system power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an active \u003cstrong\u003eBECKHOFF IP1012-B318\u003c\/strong\u003e module, record the physical address and PROFIBUS network configuration parameters before removal. Disconnect power from the module and downstream devices. Unscrew all M12 and M8 connectors, then unmount the physical housing. Mount the replacement module, reconnect all interfaces securely, and verify the network address configuration via the controller or KS2000 setup before re-commissioning the machine.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106457346411,"sku":"IP1012-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1012-b318-5hvyrtxgasr.png?v=1776244895","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1012-b318-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}