{"product_id":"beckhoff-ip1502-b200-lightbus-fieldbus-box","title":"Beckhoff IP1502-B200 Lightbus Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized industrial systems requiring high-speed pulse acquisition utilize the \u003cstrong\u003eIP1502-B200\u003c\/strong\u003e for reliable signal processing directly in the field. This high-performance Fieldbus Box serves as a dual-channel digital input counter module designed to interface seamlessly with Beckhoff Lightbus networks. It processes incoming pulse trains and binary signals up to a maximum frequency of 100 kHz, making it highly effective for positioning, frequency measurement, and rapid counting applications.\u003c\/p\u003e\n\u003cp\u003eConstructed within a rugged, moisture-resistant housing, this module carries an IP67 protection rating, allowing direct machine mounting without the protection of a control cabinet. The integration of standard M12 connectors ensures quick installation and excellent resistance to mechanical vibration and environmental stress.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo independent high-speed digital counter channels.\u003c\/li\u003e\n  \u003cli\u003eLightbus fieldbus interface for rapid deterministic communication.\u003c\/li\u003e\n  \u003cli\u003eMaximum input frequency of 100 kHz for precise pulse capture.\u003c\/li\u003e\n  \u003cli\u003eIndustrial M12 screw connection technology for reliable signal routing.\u003c\/li\u003e\n  \u003cli\u003eIP67-rated enclosure suitable for harsh industrial field environments.\u003c\/li\u003e\n  \u003cli\u003eDirect machine installation eliminates localized terminal boxes and reduces cabling costs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFlow meter pulse monitoring and liquid volume calculation.\u003c\/li\u003e\n  \u003cli\u003eRotational speed measurement and shaft encoder integration.\u003c\/li\u003e\n  \u003cli\u003eHigh-speed parts counting in packaging and bottling plants.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems requiring localized high-frequency sensor inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003eIP1502-B200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Counter Module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eLightbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Frequency\u003c\/td\u003e\n      \u003ctd\u003e100 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Interface\u003c\/td\u003e\n      \u003ctd\u003eM12 screw connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (including typical export packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal operation and to maintain the physical protection of the device, follow these installation procedures:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the module directly onto a flat machine surface or mounting profile using appropriate fastening screws.\u003c\/li\u003e\n  \u003cli\u003eEnsure all unused M12 mating ports are sealed with protective caps to preserve the IP67 environmental rating.\u003c\/li\u003e\n  \u003cli\u003eRoute high-frequency signal lines separate from high-voltage power cables to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eEstablish a low-impedance ground connection from the module's ground terminal to the machine frame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106470289771,"sku":"IP1502-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1502-b200-fld2i2apwbg.png?v=1776244903","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1502-b200-lightbus-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}