{"product_id":"beckhoff-ip1502-b528-fieldbus-box","title":"BECKHOFF IP1502-B528 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP1502-B528 is a decentralized Fieldbus Box designed for industrial automation environments. This device integrates two digital input channels along with a counter function operating at a frequency of up to 100 kHz, powered by a 24 V DC nominal supply. Engineered for machine-level installation without control cabinets, the IP1502-B528 communicates via the DeviceNet protocol and features an integrated T-connector for streamlined network integration and cabling.\u003c\/p\u003e\n\u003cp\u003eEquipped with M12 connection technology, the Fieldbus Box facilitates reliable signal acquisition and decentralization directly at the process level. Its compact, robust housing provides protection against harsh industrial conditions, making it well-suited for distributed modular machine architectures requiring deterministic fieldbus communication and high-speed counting capabilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized Fieldbus Box architecture for cabinet-free machine integration\u003c\/li\u003e\n  \u003cli\u003eTwo digital input channels for standard signal acquisition\u003c\/li\u003e\n  \u003cli\u003eIntegrated counter function with a frequency up to 100 kHz\u003c\/li\u003e\n  \u003cli\u003eDeviceNet communication interface for network connectivity\u003c\/li\u003e\n  \u003cli\u003eIntegrated T-connector for simplified bus topology wiring\u003c\/li\u003e\n  \u003cli\u003eM12 connection technology for secure, industrial-grade sensor and fieldbus interfacing\u003c\/li\u003e\n  \u003cli\u003e24 V DC field-side power supply compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized digital signal acquisition in modular machine building\u003c\/li\u003e\n  \u003cli\u003eHigh-speed counting and frequency measurement tasks in automated production lines\u003c\/li\u003e\n  \u003cli\u003eDistributed industrial networks utilizing DeviceNet communication protocols\u003c\/li\u003e\n  \u003cli\u003eHarsh industrial environments requiring cabinet-free machine-level mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP1502-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Input Channels\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCounter Function\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCounting Frequency\u003c\/td\u003e\n      \u003ctd\u003e100 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Connections\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eM12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Connection\u003c\/td\u003e\n      \u003ctd\u003eIntegrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before beginning any mechanical mounting or electrical wiring work.\u003c\/li\u003e\n  \u003cli\u003eInspect the IP1502-B528 housing, M12 connectors, and integrated T-connector for any signs of transit damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely to a flat surface or machine frame using appropriate fixing elements.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC power supply and verify correct voltage polarity before energizing the segment.\u003c\/li\u003e\n  \u003cli\u003eAttach the DeviceNet network cables utilizing the integrated T-connector and M12 interfaces, ensuring proper shielding and termination resistors where required.\u003c\/li\u003e\n  \u003cli\u003eConnect sensors and input devices to the designated M12 digital input and counter channels.\u003c\/li\u003e\n  \u003cli\u003ePerform a comprehensive commissioning check of the DeviceNet network communication and input signal acquisition via the controller configuration tools.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106466652523,"sku":"IP1502-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1502-b528-f1ilio1tpu4.png?v=1776244907","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip1502-b528-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}