{"product_id":"beckhoff-ip2001-b200-fieldbus-box","title":"BECKHOFF IP2001-B200 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2001-B200\u003c\/strong\u003e is an industrial Fieldbus Box module designed to interface digital control commands with decentralized field actuators. Operating as an 8-channel digital output unit, this device allows direct, local deployment of I\/O processing on machinery, significantly reducing cabling requirements inside central control enclosures.\u003c\/p\u003e\n\u003cp\u003eEquipped with a Lightbus communication interface, this Fieldbus Box utilizes fiber optic technology to ensure high-speed data transmission and absolute resistance to electromagnetic interference (EMI). Its compact housing and resilient mechanical design make it suitable for installation directly within challenging operational environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital output channels for controlling external loads.\u003c\/li\u003e\n  \u003cli\u003eLightbus system connection via high-noise-immunity fiber optic lines.\u003c\/li\u003e\n  \u003cli\u003eM8 round screw-style connector interface for compact and secure field connections.\u003c\/li\u003e\n  \u003cli\u003eRobust housing designed for decentralized, cabinet-free mounting layouts.\u003c\/li\u003e\n  \u003cli\u003eClear channel status indication for simplified diagnostic and commissioning activities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized control of binary actuators, valves, indicators, and small contactors.\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly systems requiring distributed physical I\/O hubs.\u003c\/li\u003e\n  \u003cli\u003eApplications in environments with high electromagnetic disturbance where fiber optic communication is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP2001-B200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and Electrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e8 digital outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Connection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Interface\u003c\/td\u003e\n      \u003ctd\u003eLightbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Connection Technology\u003c\/td\u003e\n      \u003ctd\u003eM8 screw connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that all power sources to the system and associated machinery are fully disconnected prior to mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely to a flat, rigid surface using appropriate mounting hardware to minimize mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003eConnect the Lightbus fiber optic cables, ensuring that connector faces are clean and free of dust to prevent signal loss.\u003c\/li\u003e\n  \u003cli\u003eWire the 24 V DC load outputs using matching M8 cables, adhering strictly to current limits per channel.\u003c\/li\u003e\n  \u003cli\u003eApply control power and verify system diagnostics via the diagnostic LEDs on the module interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106462392683,"sku":"IP2001-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2001-b200-lq1lu1dq5ib.png?v=1776244917","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2001-b200-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}