{"product_id":"beckhoff-ip2002-b310-fieldbus-box","title":"BECKHOFF IP2002-B310 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP2002-B310 is a rugged, decentralized Fieldbus Box designed for high-performance industrial automation. It features 8 digital outputs, allowing direct connection to actuators, contactors, solenoid valves, and indicators in the field. Operating on the PROFIBUS DP network, this module enables direct I\/O integration without the need for an additional protective control cabinet.\u003c\/p\u003e\n\n\u003cp\u003eHoused in a robust polyamide enclosure, the BECKHOFF IP2002-B310 offers IP65, IP66, and IP67 protection, making it highly resistant to dust, moisture, and mechanical stress. Fieldbus communication and power connections are securely routed via standardized M12 and M8 connectors, ensuring reliable performance in harsh manufacturing environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8 digital output channels with M12 screw-type connection technology.\u003c\/li\u003e\n  \u003cli\u003eIntegrated PROFIBUS DP interface supporting automatic baud rate detection up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eIndividually short-circuit proof outputs with a typical short-circuit current of 1.5 A.\u003c\/li\u003e\n  \u003cli\u003eRugged polyamide (PA6) housing providing IP65\/66\/67 protection.\u003c\/li\u003e\n  \u003cli\u003eM8 feed and downstream connectors for simplified power supply routing.\u003c\/li\u003e\n  \u003cli\u003eSupport for DP-V1 extensions and configuration via KS2000 or the controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect machine-mount control of pneumatic and hydraulic valves.\u003c\/li\u003e\n  \u003cli\u003eDecentralized control of optical indicators, sirens, and small actuators.\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O processing in heavy machinery, conveyor lines, and packaging systems.\u003c\/li\u003e\n  \u003cli\u003eAutomated manufacturing plants utilizing PROFIBUS DP network architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2002-B310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes (3.5 mm diameter for M3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Connection Type\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical Short-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003e1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eTypical 20 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 outputs (8 bits)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eNo electrical isolation between channels or channels\/control voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eFieldbus and Electrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eNo electrical isolation between control voltage and fieldbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface or Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M12 Socket, 5-pin (B-coded)\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP Fieldbus connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e8 x M12 Sockets\u003c\/td\u003e\n      \u003ctd\u003eDigital outputs (Channels 1 to 8)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M8 Male Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC Power feed supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e1 x M8 Female Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC Downstream power connection for daisy-chaining\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power sources are completely de-energized and locked out before starting the installation.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely on a flat surface using the two integrated 3.5 mm mounting holes with M3 screws.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS DP fieldbus cable to the B-coded M12 socket, ensuring proper connector alignment.\u003c\/li\u003e\n  \u003cli\u003eAttach the 24 V DC power supply to the M8 feed socket. If linking multiple modules, connect the downstream M8 socket to the next module's feed socket.\u003c\/li\u003e\n  \u003cli\u003eConnect the digital actuators to the corresponding M12 output sockets. Hand-tighten all connections to maintain the specified IP protection class.\u003c\/li\u003e\n  \u003cli\u003ePerform configuration and addressing via the KS2000 software interface or through the host PLC master controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106479825259,"sku":"IP2002-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2002-b310-fhb2wlgee4n.png?v=1776244930","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2002-b310-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}