{"product_id":"beckhoff-ip2002-b810-fieldbus-box-8-channel-digital-output-rs232","title":"BECKHOFF IP2002-B810 Fieldbus Box 8-Channel Digital Output RS232","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2002-B810\u003c\/strong\u003e is a decentralized Fieldbus Box designed to extend industrial control architectures directly into demanding field environments. Equipped with an integrated RS232 serial interface and eight digital output channels, this module acts as a robust point-to-point communication and control node. It enables direct interfacing between control computers, industrial PCs, or serial controllers and field-level actuators without requiring intermediate cabinets.\u003c\/p\u003e\n\n\u003cp\u003eOperating on a 24 V DC auxiliary and control supply, the \u003cstrong\u003eBECKHOFF IP2002-B810\u003c\/strong\u003e distributes control signals efficiently across its eight digital channels. Designed for extreme durability, the standard polyamide housing offers outstanding resistance to moisture, dust, and mechanical stress, making it an excellent choice for distributed installations in modern automated production lines, material handling systems, and assembly machinery.\u003c\/p\u003e\n\n\u003cp\u003eThe module facilitates straightforward integration via a standard RS232 connection with support for multiple baud rates, providing highly configurable serial communications through standard software tools. Standardized M12 and M8 connections secure reliable physical wiring for fieldbus signals, control power, and digital outputs.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight independent digital output channels rated at 0.5 A per channel.\u003c\/li\u003e\n  \u003cli\u003eIntegrated RS232 communication interface supporting baud rates up to 38.4 kbaud.\u003c\/li\u003e\n  \u003cli\u003eDirect machine mounting capability with high IP65, IP66, and IP67 ingress ratings.\u003c\/li\u003e\n  \u003cli\u003eShort-circuit-proof digital outputs with integrated overload diagnostics.\u003c\/li\u003e\n  \u003cli\u003ePolyamide (PA6) housing construction offering reliable physical protection in harsh environments.\u003c\/li\u003e\n  \u003cli\u003eStandardized M12 connection technology for fieldbus interface and output signals.\u003c\/li\u003e\n  \u003cli\u003eM8 feed and downstream connectors for simplified power routing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized control of solenoids, contactors, indicators, and small actuators.\u003c\/li\u003e\n  \u003cli\u003eDirect machine-level integration bypassing traditional electrical enclosures.\u003c\/li\u003e\n  \u003cli\u003ePoint-to-point serial communication links in automated production systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, conveying, and sorting equipment installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2002-B810\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Connection Type\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Types\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003eTyp. 1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e8 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eRS232 and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Interface\u003c\/td\u003e\n      \u003ctd\u003eRS232 (IPxxxx-B810, IL230x-B810)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePhysical Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Software\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 serial interface software\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Power Supply\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (Box)\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: Yes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface or Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Socket (5-pin, B-coded)\u003c\/td\u003e\n      \u003ctd\u003eRS232 communication interface connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eFeed-in socket for 24 V DC control and auxiliary power supply\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003eDownstream loop-through power supply for neighboring modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Screw Connectors\u003c\/td\u003e\n      \u003ctd\u003e8 digital output channel connections for actuator wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire industrial automation system is safely powered down and locked out before starting the installation process.\u003c\/li\u003e\n  \u003cli\u003eMount the module on a flat, vibration-resistant surface utilizing the two integrated 3.5 mm mounting holes with suitable M3 hardware.\u003c\/li\u003e\n  \u003cli\u003eVerify that the incoming control voltage supply matches the rated 24 V DC specification prior to routing connections.\u003c\/li\u003e\n  \u003cli\u003eConnect the incoming 24 V DC supply to the 4-pin M8 male feed connector and loop to adjacent modules from the M8 female socket if necessary.\u003c\/li\u003e\n  \u003cli\u003eVerify correct alignment and orientation of all M12 and M8 screw connectors. Tighten to specification to preserve the IP65\/66\/67 environmental seal.\u003c\/li\u003e\n  \u003cli\u003eSeal any unused M12 and M8 ports with verified protective caps to prevent dust, water, and debris ingress.\u003c\/li\u003e\n  \u003cli\u003eApply control power, check the status of system indicators, and establish communications via the RS232 interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106529599851,"sku":"IP2002-B810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2002-b810-tymjorttu2w.png?v=1776244933","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2002-b810-fieldbus-box-8-channel-digital-output-rs232","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}