{"product_id":"beckhoff-ip2022-b510-canopen-fieldbus-box-8-channel-digital-output","title":"BECKHOFF IP2022-B510 CANopen Fieldbus Box 8-Channel Digital Output","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2022-B510\u003c\/strong\u003e is a high-performance decentralised Fieldbus Box designed to connect digital actuators directly within CANopen network architectures. By facilitating direct machine mounting without an enclosure, this module simplifies field-level wiring and minimises control cabinet space requirements. It features 8 digital outputs that operate at 24 V DC, providing dependable control for valves, contactors, indicators, and small motor loads in industrial settings.\u003c\/p\u003e\n\n\u003cp\u003eEngineered for harsh industrial environments, the \u003cstrong\u003eBECKHOFF IP2022-B510\u003c\/strong\u003e features a rugged polyamide housing offering IP65, IP66, or IP67 protection. It communicates via CANopen using a standard 5-pin M12 connector and supports automatic baud rate detection up to 1 Mbaud. The load and control voltages are supplied via compact M8 connections with downstream loop-through capabilities, facilitating efficient daisy-chain power distribution across multiple modules.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8-channel digital output interface for direct field actuator control.\u003c\/li\u003e\n  \u003cli\u003eCANopen protocol compatibility with automatic baud rate detection from 10 kbaud up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eHigh switching capability providing up to 2 A per channel (maximum 4 A total sum current).\u003c\/li\u003e\n  \u003cli\u003eIndividually short-circuit proof outputs to protect field cabling and equipment.\u003c\/li\u003e\n  \u003cli\u003eRobust IP65\/66\/67 protection class allowing direct mounting on machinery without protective cabinets.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic monitoring and status LED indicators for rapid troubleshooting.\u003c\/li\u003e\n  \u003cli\u003eEfficient power distribution using M8 feed and downstream loop-through connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralised pneumatic and hydraulic valve control on manufacturing machinery.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling systems requiring local actuator switching.\u003c\/li\u003e\n  \u003cli\u003eDistributed packaging machinery and assembly line automation setups.\u003c\/li\u003e\n  \u003cli\u003eDirect machine-mount digital output expansions where control cabinet space is constrained.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2022-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation \/ Mounting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes, 3.5 mm diameter (for M3 screws)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 A per channel (individually short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Max. Output Current (Sum)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuxiliary Power Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTypically 30 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCANopen Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection: 10 kbaud up to 1 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcess Image Bit Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCANopen Features\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLife\/Node guarding, emergency object, variable mapping, store\/restore configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software tool or the system controller (SDOs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical \u0026amp; Isolation\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor\/auxiliary current (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; channels\/control voltage: no\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \u0026amp; Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \u0026amp; EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \u0026amp; EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface \/ Connector\u003c\/th\u003e\n      \u003cth\u003eFunction \/ Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Bus Interface (5-pin Plug)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen network interface connection. Supports standard CAN wiring.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM12 Output Connectors (Screw Type)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConnection points for the 8 digital outputs to field-level actuators.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Feed (4-pin Male)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMain power connection input for control and load voltage supplies.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eM8 Power Supply Downstream (4-pin Female)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLoop-through connector to pass control and load voltages to adjacent Fieldbus Boxes.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify System State:\u003c\/strong\u003e Ensure all electrical power sources are switched off and locked out before initiating installation or maintenance tasks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Securely install the module using the two 3.5 mm diameter fixing holes with suitable M3 screws on a flat surface or machine framework. Mounting orientation is variable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFieldbus Connection:\u003c\/strong\u003e Connect the CANopen bus line to the 5-pin M12 bus interface plug, adhering to proper CAN shielding and termination practices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Connections:\u003c\/strong\u003e Wire the actuators to the digital output M12 screw connections. Ensure the current draw does not exceed 2 A per individual channel and 4 A total.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Connect the 24 V DC power feed to the M8 male socket. If using downstream modules, daisy-chain the power from the downstream M8 female socket.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Apply power, configure the CANopen node address and baud rate via the controller interface or KS2000 software, and verify status via the integrated diagnostic LEDs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106466455915,"sku":"IP2022-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2022-b510-244ivvhzcsp.png?v=1776244953","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2022-b510-canopen-fieldbus-box-8-channel-digital-output","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}