{"product_id":"beckhoff-ip2041-b528-fieldbus-box","title":"BECKHOFF IP2041-B528 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for decentralized industrial automation architectures, the \u003cstrong\u003eIP2041-B528\u003c\/strong\u003e digital output module facilitates direct, cabinet-free connection of actuators in the field. This rugged \u003cstrong\u003efieldbus box\u003c\/strong\u003e interfaces seamlessly with DeviceNet networks, allowing control systems to actuate up to eight digital field devices with minimal propagation delay. By placing the I\/O interface directly on the machinery, it significantly reduces cabling overhead and simplifies local troubleshooting.\u003c\/p\u003e\n\n\u003cp\u003eThe module features eight high-capacity digital outputs rated at 24 V DC, each capable of switching loads up to 2 A, with a maximum aggregate sum current of 12 A across all channels. Connectivity is established via standard M8 circular connectors, ensuring vibration-resistant connections. System integration is further streamlined by an integrated DeviceNet T-connector, allowing direct loop-through configuration of the network cable without external splitting hardware.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Current Capacity:\u003c\/strong\u003e Delivers up to 2 A per digital output channel for demanding actuator loads.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeviceNet Integration:\u003c\/strong\u003e Built-in DeviceNet protocol support with an integrated T-connector for efficient line-topology cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDecentralized Design:\u003c\/strong\u003e Compact, field-mountable enclosure suitable for installation directly on machinery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust M8 Connections:\u003c\/strong\u003e Industrial-grade M8 sockets secure reliable signal transmission under high physical stress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Aggregate Current:\u003c\/strong\u003e Supports a maximum sum current of 12 A, enabling simultaneous high-load operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaterial handling and automated conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eAssembly lines and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003ePneumatic valve terminal control.\u003c\/li\u003e\n  \u003cli\u003eRobotic end-of-arm tooling and auxiliary control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP2041-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Digital Output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 digital outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Output Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current per Channel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Aggregate Sum Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eActuator Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 circular connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNetwork Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated T-connector (DeviceNet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Standard)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Fasten the fieldbus box securely to a flat surface using the integrated mounting holes to prevent vibration-induced mechanical wear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Use shielded cables for the DeviceNet interface to maintain optimal signal integrity. Ensure M8 mating connectors are torque-tightened to preserve the module's environmental sealing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the functional earth terminal directly to the machine frame or a low-impedance ground point to minimize electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Routing:\u003c\/strong\u003e Verify that the 24 V DC power source can sustain both the continuous channel loads and potential peak startup currents without voltage drops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106463506795,"sku":"IP2041-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2041-b528-ovr13zfanft.png?v=1776244972","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2041-b528-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}