{"product_id":"beckhoff-ip2042-b800-fieldbus-box","title":"BECKHOFF IP2042-B800 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP2042-B800 is a decentralized industrial Fieldbus Box featuring 8 digital outputs designed for direct machine-level installation without control cabinets. Operating on an RS485 communication protocol via an open, documented protocol, this IP65\/66\/67 rated module integrates seamlessly into distributed automation architectures. It provides robust signal handling in harsh industrial environments where direct mounting on machinery is required.\u003c\/p\u003e\n\u003cp\u003eThis compact device accommodates ohmic, inductive, and lamp loads with a nominal output voltage of 24 V DC. Connection technology utilizes M12 screw-type connectors for digital outputs, an M12 B-coded socket for the bus interface, and M8 male sockets for power supply feeds. Configuration is supported via the KS2000 software tool, making the IP2042-B800 suitable for modular machine building and decentralized plant topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e8-channel digital output block with M12 screw-type connections\u003c\/li\u003e\n  \u003cli\u003eRS485 fieldbus interface utilizing an open, documented protocol\u003c\/li\u003e\n  \u003cli\u003eNominal output voltage of 24 V DC with individual short-circuit proof channels\u003c\/li\u003e\n  \u003cli\u003eTotal maximum output current of 12 A distributed across channel groups\u003c\/li\u003e\n  \u003cli\u003eRugged PA6 polyamide housing with IP65, IP66, and IP67 protection ratings\u003c\/li\u003e\n  \u003cli\u003eDirect machine mounting capability via variable installation positions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized industrial automation and machine control architectures\u003c\/li\u003e\n  \u003cli\u003eModular machine building requiring cabinet-free I\/O distribution\u003c\/li\u003e\n  \u003cli\u003eActuator control for ohmic, inductive, and lamp load configurations\u003c\/li\u003e\n  \u003cli\u003eHarsh industrial environments requiring high protection class IP65\/66\/67 enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2042-B800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eOpen, documented protocol\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Connections\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e2 A per channel, individually short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Current Max.\u003c\/td\u003e\n      \u003ctd\u003e12 A (channel 0 to 3: sum 4 A, 4+5: sum 4 A, 6+7: sum 4 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003eTyp. 4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e8 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Power Supply\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 mm square\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003eMax. 1200 m (depending on baud rate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 2 x M8 male socket, 4-pin; no downstream connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors, max. 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes 3.5 mm diameter for M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs (8 channels)\u003c\/td\u003e\n      \u003ctd\u003eM12 screw-type connectors for actuator connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded for RS485 communication\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Feed\u003c\/td\u003e\n      \u003ctd\u003e2 x M8 male socket, 4-pin for control voltage input\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the system power supply is completely de-energized before beginning installation or wiring work.\u003c\/li\u003e\n  \u003cli\u003eInspect the BECKHOFF IP2042-B800 housing, M12 connectors, and M8 sockets for any signs of transit damage.\u003c\/li\u003e\n  \u003cli\u003eMount the unit securely onto a flat machine surface using the two 3.5 mm fixing holes designated for M3 screws in a variable installation position.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage to the M8 power supply feed sockets, ensuring correct polarity and adherence to voltage tolerances (-15 percent \/ +20 percent).\u003c\/li\u003e\n  \u003cli\u003eConnect the RS485 fieldbus line using a shielded copper cable (2 x 0.25 mm square) to the 5-pin B-coded M12 bus socket.\u003c\/li\u003e\n  \u003cli\u003eAttach actuators to the 8 digital output M12 ports, ensuring that individual channel currents do not exceed 2 A and total current limits are respected.\u003c\/li\u003e\n  \u003cli\u003ePerform a complete wiring inspection and verify bus termination before restoring system power and initiating configuration via the KS2000 software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106459738475,"sku":"IP2042-B800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2042-b800-usjmjfuhdv2.png?v=1776244985","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2042-b800-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}