{"product_id":"beckhoff-ip2301-b510-fieldbus-box","title":"BECKHOFF IP2301-B510 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2301-B510\u003c\/strong\u003e is a high-performance, decentralized Fieldbus Box designed for direct machine installation without a control cabinet. By combining 4 digital inputs and 4 digital outputs in a single unit, this device enables direct localized acquisition and control of proximity sensors, switches, and small actuator loads. It features an integrated CANopen interface to facilitate fast, deterministic communication across decentralized automation systems.\u003c\/p\u003e\n\n\u003cp\u003eHoused in a rugged, moisture-resistant enclosure, the \u003cstrong\u003eBECKHOFF IP2301-B510\u003c\/strong\u003e uses standardized M8 connections for all I\/O signals, ensuring quick, error-free wiring. Its compact physical footprint and direct fieldbus integration reduce wiring overhead, simplify troubleshooting, and lower commissioning times in robust, distributed automation topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect CANopen network integration with automatic baud rate detection up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003e4 digital inputs with 3.0 ms input filter time to minimize contact bounce and signal noise.\u003c\/li\u003e\n  \u003cli\u003e4 short-circuit-proof digital outputs, delivering up to 0.5 A per channel for reliable valve and load control.\u003c\/li\u003e\n  \u003cli\u003eM8 screw-type connection points for high vibrational stability on localized I\/O signals.\u003c\/li\u003e\n  \u003cli\u003eIP65, IP66, and IP67 ingress protection ratings, allowing for direct-on-machine installation.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in diagnostic support, including SDO configuration access through software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine tool control and remote sensor clusters.\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling control where high ingress protection is required.\u003c\/li\u003e\n  \u003cli\u003eAutomated sorting systems and localized pneumatic valve terminal control.\u003c\/li\u003e\n  \u003cli\u003eAssembly lines and packaging machinery operating in harsh environmental conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral and System Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP2301-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (I\/O Module)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software or host controller (SDOs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCANopen Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eCANopen (IPxxxx-B51x series specification)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Data Objects (PDOs)\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive PDOs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional Features\u003c\/td\u003e\n      \u003ctd\u003eNode guarding, life guarding, emergency object, variable mapping, store\/restore\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eM8, screw-type connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Filter Time\u003c\/td\u003e\n      \u003ctd\u003e3.0 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (6 mA input current conforming to EN 61131-2, Type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n      \u003ctd\u003eDerived from control voltage, max. 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eM8, screw-type connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type Compatibility\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, and lamp loads\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical Short-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003e1.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eTyp. 20 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Isolation\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket (4-pin feed); 1 x M8 female socket (4-pin downstream)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (Internal)\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; control voltage\/inputs or outputs: none\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e2 fixing holes (3.5 mm diameter) for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, and IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 and EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 and EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify System Compatibility:\u003c\/strong\u003e Check that the host CANopen configuration matches the parameters of the module prior to electrical integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIsolate Power:\u003c\/strong\u003e Ensure all auxiliary control and load power sources are completely de-energized before mounting.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Attach the module to a flat, rigid machine surface using two standard M3 screws through the 3.5 mm mounting holes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterface Connections:\u003c\/strong\u003e Secure the 5-pin M12 CANopen connector and ensure correct shielding has been implemented.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Wire the 24 V DC control voltage through the M8 4-pin male socket, extending to downstream devices if necessary using the M8 female downstream port.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Device Wiring:\u003c\/strong\u003e Screw down M8 cables from digital inputs and outputs securely to achieve the rated IP67 protection class.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Power up the unit and perform automatic address identification or assign node parameters through the controller interface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106501124459,"sku":"IP2301-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2301-b510-l1faf1vglmw.png?v=1776244994","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2301-b510-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}