{"product_id":"beckhoff-ip2301-b528-fieldbus-box","title":"BECKHOFF IP2301-B528 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP2301-B528 is a decentralized industrial fieldbus module from the Fieldbus Box product family, designed for direct machine-level mounting without the need for a control cabinet. This device integrates four digital inputs and four digital outputs, providing reliable signal processing for automation systems operating in harsh industrial environments. It connects directly to a DeviceNet network and features an integrated T-connector for straightforward network topology implementation.\u003c\/p\u003e\n\u003cp\u003eEngineered for decentralized architectures, the IP2301-B528 utilizes M8 connectors for process signal interfacing, reducing cabling overhead and streamlining installation on machine frames. Operating on a 24 V DC supply voltage, the module is equipped to handle standard industrial sensor and actuator requirements with a 0.5 A output current capability per channel. Its robust physical protection and direct-mount capability make it suitable for distributed control applications where space and environmental resilience are critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized Fieldbus Box architecture designed for machine-level installation without a control cabinet\u003c\/li\u003e\n  \u003cli\u003eIntegrated DeviceNet communication interface with a built-in T-connector for streamlined network cabling\u003c\/li\u003e\n  \u003cli\u003e4 digital inputs and 4 digital outputs for standard discrete sensor and actuator connectivity\u003c\/li\u003e\n  \u003cli\u003eM8 connector technology for secure and compact process signal wiring\u003c\/li\u003e\n  \u003cli\u003eStandard 24 V DC system and peripheral supply voltage\u003c\/li\u003e\n  \u003cli\u003e0.5 A switching capacity per digital output channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine automation and modular plant engineering\u003c\/li\u003e\n  \u003cli\u003eAutomated assembly lines and material handling systems requiring cabinet-free I\/O distribution\u003c\/li\u003e\n  \u003cli\u003eConveyor technology and sorting equipment with distributed sensor placement\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery operating on DeviceNet communication networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2301-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFilter \/ Response Time\u003c\/td\u003e\n      \u003ctd\u003e3 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Connection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology (Signals)\u003c\/td\u003e\n      \u003ctd\u003eM8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNetwork Interface\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that the system power and external supply voltages are fully de-energized before beginning any mechanical mounting or electrical wiring work.\u003c\/li\u003e\n  \u003cli\u003eInspect the IP2301-B528 housing, M8 connectors, and integrated T-connector for any visible transit damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a flat machine surface or profile using the designated mounting holes to withstand operational vibration.\u003c\/li\u003e\n  \u003cli\u003eConnect the DeviceNet network cable using the integrated T-connector, ensuring correct bus termination according to network requirements.\u003c\/li\u003e\n  \u003cli\u003eAttach digital sensors and actuators to the M8 input and output ports, verifying correct pin assignments and cable shielding practices.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC power supply to the designated power terminals, checking polarity before restoring power.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and verify operational status via the device diagnostic LEDs and the master controller configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106479464811,"sku":"IP2301-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2301-b528-llgz3tzifrl.png?v=1776244996","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2301-b528-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}