{"product_id":"beckhoff-ip2301-b800-fieldbus-box-digital-i-o-module","title":"BECKHOFF IP2301-B800 Fieldbus Box Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP2301-B800 is a compact Fieldbus Box module designed for direct machine mounting in distributed automation systems. It integrates four digital inputs and four digital outputs within a sealed, IP67-rated enclosure, enabling reliable signal processing without the need for an external control cabinet. The module utilizes an RS485 serial communication interface running an open, documented protocol, allowing direct integration into host control systems or serial fieldbus networks.\u003c\/p\u003e\n\n\u003cp\u003eOperating from a 24 V DC supply, the module processes binary sensor signals using a 3.0 ms input filter conforming to EN 61131-2 Type 2 specifications. The four digital outputs support load currents of up to 0.5 A per channel for resistive, inductive, or lamp loads, with built-in short-circuit proofing and reverse polarity protection. Signal connections are established using industrial M8 screw-type connectors, and LED status indicators on the front panel provide clear operational diagnostics for each channel and bus communication state.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCombines 4 digital inputs and 4 digital outputs in a single compact housing\u003c\/li\u003e\n\u003cli\u003eRS485 serial fieldbus communication supporting transfer rates up to 38.4 kbaud\u003c\/li\u003e\n\u003cli\u003eHigh ingress protection rated at IP65, IP66, and IP67 for harsh environments\u003c\/li\u003e\n\u003cli\u003eIndividually short-circuit proof 0.5 A digital outputs with inverse polarity protection\u003c\/li\u003e\n\u003cli\u003eDirect M8 screw-type connection for industrial sensors and actuators\u003c\/li\u003e\n\u003cli\u003eIntegrated feed and downstream M8 power connectors for looped control voltage distribution\u003c\/li\u003e\n\u003cli\u003eConfigurable operating parameters using BECKHOFF KS2000 software\u003c\/li\u003e\n\u003cli\u003eOptical status LEDs indicating bus activity and I\/O switching states\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBECKHOFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIP2301-B800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldbus Box (Compact Box)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Status\u003c\/td\u003e\n\u003ctd\u003eService phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Time\u003c\/td\u003e\n\u003ctd\u003e3.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage \"0\"\u003c\/td\u003e\n\u003ctd\u003e-3 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage \"1\"\u003c\/td\u003e\n\u003ctd\u003e11 to 30 V (6 mA input current, EN 61131-2, type 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply\u003c\/td\u003e\n\u003ctd\u003eFrom control voltage (US), max. 0.5 A total, short-circuit proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDigital Outputs\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Types\u003c\/td\u003e\n\u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n\u003ctd\u003eTyp. 1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Current (UP)\u003c\/td\u003e\n\u003ctd\u003eTyp. 20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eFieldbus Interface\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Type\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n\u003ctd\u003eOpen, documented protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n\u003ctd\u003e9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface Connector\u003c\/td\u003e\n\u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Medium\u003c\/td\u003e\n\u003ctd\u003eShielded copper cable, 2 x 0.25 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eVia KS2000 software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n\u003ctd\u003e4 inputs + 4 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Power\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBox Supply Current (US)\u003c\/td\u003e\n\u003ctd\u003e45 mA + sensor consumption (max. 0.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003eFeed: 1 x M8 male socket, 4-pin, A-coded; Downstream: 1 x M8 female socket, 4-pin, A-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eControl voltage \/ fieldbus: yes; Channels \/ control voltage: no; Between channels: no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePA6 (polyamide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Format\u003c\/td\u003e\n\u003ctd\u003eStandard housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e2 fixing holes, 3.5 mm diameter for M3 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n\u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n\u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n\u003ctd\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106499617131,"sku":"IP2301-B800","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2301-b800-rsl1a0k3qir.png?v=1776244998","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2301-b800-fieldbus-box-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}