{"product_id":"beckhoff-ip2312-b510-canopen-fieldbus-box","title":"BECKHOFF IP2312-B510 CANopen Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2312-B510\u003c\/strong\u003e is a high-performance, IP67-rated Fieldbus Box designed for decentralized automation architectures. Operating as a robust I\/O interface, this module facilitates direct communication with CANopen networks. It integrates 4 digital inputs and 4 digital outputs, enabling direct connection to sensors and actuators in challenging industrial environments without the need for an additional protective control cabinet.\u003c\/p\u003e\n\u003cp\u003eBy utilizing standard M12 connection technology, the \u003cstrong\u003eIP2312-B510\u003c\/strong\u003e ensures secure, vibration-resistant signal transmission. Its compact and ruggedized design makes it highly suitable for distributed field installations where space optimization and direct physical mounting onto machinery are critical operational requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration into CANopen industrial networks via the B510 interface.\u003c\/li\u003e\n  \u003cli\u003e4 digital inputs (24 V DC) for reliable sensor data acquisition.\u003c\/li\u003e\n  \u003cli\u003e4 digital outputs (24 V DC, 0.5 A per channel) for robust actuator control.\u003c\/li\u003e\n  \u003cli\u003eStandardized industrial M12 round connectors for durable connection pathways.\u003c\/li\u003e\n  \u003cli\u003eIP67-rated housing offering protection against dust, water, and mechanical stress.\u003c\/li\u003e\n  \u003cli\u003eDecentralized mechanical layout to minimize control cabinet footprint and wiring overhead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed machinery control and decentralized field installations.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems, conveyors, and sorting equipment.\u003c\/li\u003e\n  \u003cli\u003eDirect sensor-to-controller interfacing in wet, dusty, or demanding environments.\u003c\/li\u003e\n  \u003cli\u003eDistributed physical I\/O expansion in localized CANopen networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2312-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIP Protection Class\u003c\/td\u003e\n      \u003ctd\u003eIP67\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Connection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eCANopen (B510 interface)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003eM12 round connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the received model is the exact \u003cstrong\u003eIP2312-B510\u003c\/strong\u003e matching your system schematics.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies and fieldbus lines are completely de-energized before mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a flat machine surface using the integrated mounting brackets to preserve the IP67 sealing integrity.\u003c\/li\u003e\n  \u003cli\u003eConnect the CANopen network bus and the corresponding digital I\/O lines using correct M12 mating connectors. Ensure the connectors are threaded cleanly and tightened to the appropriate torque.\u003c\/li\u003e\n  \u003cli\u003eEstablish proper potential grounding and verify fieldbus shielding to protect against electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eApply power to the system and configure the CANopen node address and baud rate parameters according to the master controller configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106528813419,"sku":"IP2312-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2312-b510-v0m10e4dma3.png?v=1776245027","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2312-b510-canopen-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}