{"product_id":"beckhoff-ip2312-b528-fieldbus-box","title":"BECKHOFF IP2312-B528 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP2312-B528\u003c\/strong\u003e Fieldbus Box is a decentralized industrial input\/output module designed for harsh automation environments requiring robust machine-level integration. Engineered for direct mounting on machine frames without the need for control cabinets, this device provides reliable signal processing and communication within distributed control architectures.\u003c\/p\u003e\n\u003cp\u003eThis IP2312-B528 module combines digital input and digital output channels with native DeviceNet fieldbus connectivity, enabling seamless integration into established automation networks. Featuring integrated T-connectors for power and bus distribution, the unit simplifies field wiring topologies and reduces installation effort in complex industrial machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized Fieldbus Box architecture designed for machine-level mounting without control cabinets\u003c\/li\u003e\n  \u003cli\u003eIntegrated DeviceNet communication interface for connection to industrial fieldbus networks\u003c\/li\u003e\n  \u003cli\u003eEquipped with combined digital input and digital output channels for mixed signal handling\u003c\/li\u003e\n  \u003cli\u003eIntegrated T-connector design for streamlined power and bus line routing directly at the device\u003c\/li\u003e\n  \u003cli\u003eRugged industrial housing suitable for demanding operational environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed machine automation and modular production lines\u003c\/li\u003e\n  \u003cli\u003eCabinet-free machine assembly and decentralized plant architectures\u003c\/li\u003e\n  \u003cli\u003eMaterial handling and conveyor systems requiring robust field-level I\/O\u003c\/li\u003e\n  \u003cli\u003eAutomated manufacturing cells utilizing DeviceNet communication networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP2312-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Inputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDigital Outputs\u003c\/td\u003e\n      \u003ctd\u003e4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunication and Performance\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003eM12 connectors with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the BECKHOFF IP2312-B528 exact model number matches system engineering documentation before installation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies and fieldbus lines are completely de-energized prior to mechanical mounting or electrical connection.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a clean, flat machine surface or profile using appropriate fasteners.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC power supply and DeviceNet communication lines using the designated M12 connectors and integrated T-connectors.\u003c\/li\u003e\n  \u003cli\u003eVerify correct wiring polarity, signal assignments, and bus termination before restoring power to the system.\u003c\/li\u003e\n  \u003cli\u003eCommission the module within the master control environment and verify communication status via device diagnostics.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106470650219,"sku":"IP2312-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2312-b528-1goo2dzai52.png?v=1776245029","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip2312-b528-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}