{"product_id":"beckhoff-ip3102-b310-profibus-dp-fieldbus-box","title":"BECKHOFF IP3102-B310 PROFIBUS DP Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP3102-B310\u003c\/strong\u003e is a high-performance Fieldbus Box designed to bridge analog inputs directly to a PROFIBUS DP network. Developed for decentralized automation architectures, this module enables direct sensor connection in the field without the need for a protective control cabinet. By utilizing standardized industrial connections, it facilitates rapid installation, minimizes wiring complexity, and reduces system footprint.\u003c\/p\u003e\n\u003cp\u003eOperating as a PROFIBUS DP slave, the \u003cstrong\u003eBECKHOFF IP3102-B310\u003c\/strong\u003e supports automatic baud rate detection up to 12 Mbaud, ensuring integration into existing communication networks. Its design features an IP67-rated enclosure, providing protection against dust, water, and mechanical stress in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration with PROFIBUS DP networks supporting DP-V1 extensions.\u003c\/li\u003e\n  \u003cli\u003eAutomatic fieldbus baud rate detection up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eIndustrial M12 fieldbus connection technology with B-coding.\u003c\/li\u003e\n  \u003cli\u003eM8 power supply connections with loop-through capability for downstream modules.\u003c\/li\u003e\n  \u003cli\u003eFlexible parameter configuration via the BECKHOFF KS2000 software or directly through the fieldbus controller.\u003c\/li\u003e\n  \u003cli\u003eHigh-density IP65, IP66, and IP67 protection class for decentralized, cabinet-free mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized data acquisition and analog sensor integration.\u003c\/li\u003e\n  \u003cli\u003eCabinet-free machine-mount installation in assembly lines and conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eProcess monitoring and field-level signal processing in harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP3102-B310\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box (Analog Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Option\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 configuration software or the controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003eDependent on I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No; Control voltage\/inputs: Dependent on I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eFieldbus and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP (supports DP-V1 extensions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface Connection\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Time\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.5 ms with 10 stations (each with 32-bit input and output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 and EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity and Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 and EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Socket (5-pin, B-coded)\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP fieldbus communication connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control voltage input feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Connector (4-pin)\u003c\/td\u003e\n      \u003ctd\u003e24 V DC downstream control voltage loop-through\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem De-energization:\u003c\/strong\u003e Prior to mounting, installation, or wiring, ensure all electrical power sources to the system are completely switched off.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePhysical Mounting:\u003c\/strong\u003e Securely mount the module directly to the machine frame or mounting plate using the integrated mounting holes. Ensure the surface is flat to avoid stress on the housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFieldbus Connection:\u003c\/strong\u003e Connect the PROFIBUS DP line to the B-coded M12 interface. Properly tighten the connector collar to ensure an IP67 environmental seal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Connection:\u003c\/strong\u003e Feed the 24 V DC control voltage into the M8 male connector. If daisy-chaining power, connect the downstream M8 female connector to the next fieldbus box.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure proper grounding through the mounting screws or a dedicated ground connection to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommissioning Check:\u003c\/strong\u003e Apply power and observe the status LEDs to verify communication and operating state.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106437390699,"sku":"IP3102-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3102-b310-hofikt1s2ok.png?v=1776245076","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip3102-b310-profibus-dp-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}