{"product_id":"beckhoff-ip3102-b318-profibus-dp-fieldbus-box","title":"BECKHOFF IP3102-B318 PROFIBUS DP Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP3102-B318 is a specialized Fieldbus Box engineered for direct signal acquisition and communication within PROFIBUS DP networks. This industrial field module enables direct connections to machine architectures without the requirement of an electrical control cabinet, optimizing field-level deployment and decentralization.\u003c\/p\u003e\n\n\u003cp\u003eDevice configuration is supported directly through the master controller or via the BECKHOFF KS2000 software. The integration of DP-V1 extensions allows for expanded acyclic parameterization and diagnostics, providing clear, detailed status and diagnostic information back to the control station.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for survival in demanding physical environments, the IP3102-B318 features a fully sealed enclosure rated to IP65, IP66, and IP67 standards. Standardized M8 and M12 connectors simplify wiring configurations, supporting high-speed transmission rates up to 12 Mbaud with automatic detection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect field installation capability, bypassing the need for a protective junction box\u003c\/li\u003e\n  \u003cli\u003ePROFIBUS DP communication with automatic baud rate detection up to 12 Mbaud\u003c\/li\u003e\n  \u003cli\u003eSupports DP-V1 extensions for flexible parameterization and device diagnostic tasks\u003c\/li\u003e\n  \u003cli\u003eIntegrated M12 B-coded bus interface with built-in T-connector configuration\u003c\/li\u003e\n  \u003cli\u003eStandardized M8 power connections for direct power feed and downstream loop-through routing\u003c\/li\u003e\n  \u003cli\u003eConfiguration options using the KS2000 interface or via the control system configuration utility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDistributed industrial control systems using PROFIBUS DP networking architectures\u003c\/li\u003e\n  \u003cli\u003eDecentralized input monitoring in machine building and processing lines\u003c\/li\u003e\n  \u003cli\u003eIn-field instrumentation integration requiring ingress protection up to IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP3102-B318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Option\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 or the controller (DP-V1 extensions supported)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Interface\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket (5-pin), 1 x M12 plug (5-pin), integrated T-connector, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, 2 x 0.25 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Time\u003c\/td\u003e\n      \u003ctd\u003eApproximately 0.5 ms with 10 stations (each with 32-bit input and output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Power Supply\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + current consumption of sensors (maximum 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: No; Control voltage\/inputs or outputs: According to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity and Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInterface or Terminal\u003c\/td\u003e\n      \u003ctd\u003eFunction\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Connection (M12 Plug\/Socket)\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP communication line, B-coded, featuring an integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Feed (M8 Male)\u003c\/td\u003e\n      \u003ctd\u003e24 V DC primary control voltage inlet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Downstream (M8 Female)\u003c\/td\u003e\n      \u003ctd\u003eLoop-through supply connection to downstream Fieldbus Box modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the physical BECKHOFF IP3102-B318 hardware matches the requirements of your control system layout before proceeding.\u003c\/li\u003e\n  \u003cli\u003eEnsure all upstream and field-side electrical power sources are fully de-energized prior to mounting or connecting the unit.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the module on the machine structure or frame using suitable mounting fasteners, ensuring the physical installation orientation matches your application layout.\u003c\/li\u003e\n  \u003cli\u003eConnect the PROFIBUS DP network cables to the B-coded M12 connections, utilizing the integrated T-connector path as required by the network topology.\u003c\/li\u003e\n  \u003cli\u003eVerify and apply the 24 V DC control voltage to the 4-pin M8 male connector, and configure downstream daisy-chain power cabling if applicable.\u003c\/li\u003e\n  \u003cli\u003eVerify the shielding and physical grounding parameters are correctly established for compliance with EMC immunity standards.\u003c\/li\u003e\n  \u003cli\u003eEnergize the system and use the master controller configuration software or KS2000 utility to establish baseline operational status and parameters.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106444337515,"sku":"IP3102-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3102-b318-in3mcephrug.png?v=1776245077","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip3102-b318-profibus-dp-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}