{"product_id":"beckhoff-ip3202-b730-fieldbus-box","title":"BECKHOFF IP3202-B730 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP3202-B730\u003c\/strong\u003e is a heavy-duty Fieldbus Box designed for direct connection to serial RTU\/ASCII networks in demanding industrial environments. This compact and rugged I\/O module enables reliable integration of peripheral signals into fieldbus systems without requiring a protective control cabinet.\u003c\/p\u003e\n\u003cp\u003eEquipped with an integrated RS485\/RS232 serial interface utilizing RTU or ASCII protocols, the \u003cstrong\u003eBECKHOFF IP3202-B730\u003c\/strong\u003e supports a wide range of baud rates for flexible communication. Its durable housing is certified to IP65, IP66, and IP67 protection ratings, making it highly resistant to wet, dusty, and challenging operating conditions. System configuration is simplified through physical address selection switches or using the KS2000 configuration software.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration into serial networks using Modbus RTU or ASCII protocol standards\u003c\/li\u003e\n  \u003cli\u003eDurable IP65, IP66, and IP67-rated housing for decentralized, cabinet-free installation\u003c\/li\u003e\n  \u003cli\u003eFlexible data transfer rates ranging from 150 baud up to 38,400 baud\u003c\/li\u003e\n  \u003cli\u003eEasy network addressing via integrated physical address selection switches\u003c\/li\u003e\n  \u003cli\u003eM12 B-coded bus interface and industrial M8 power connections for reliable wiring\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation between control voltage and the fieldbus network\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized industrial automation and process control systems\u003c\/li\u003e\n  \u003cli\u003eMachine-mount applications requiring direct physical resistance to moisture and dust\u003c\/li\u003e\n  \u003cli\u003eSerial communication networks in manufacturing and material handling systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP3202-B730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtocol\u003c\/td\u003e\n      \u003ctd\u003eRTU\/ASCII\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd\u003eAddress selection switch or KS2000 software\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e150, 300, 600, 1200, 2400, 4800, 9600, 19,200, 38,400 baud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: yes; Control voltage\/inputs or outputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the exact model \u003cstrong\u003eIP3202-B730\u003c\/strong\u003e matches your system configuration and wiring drawings.\u003c\/li\u003e\n  \u003cli\u003eEnsure all electrical systems are fully de-energized and locked out before commencing installation or maintenance.\u003c\/li\u003e\n  \u003cli\u003eInspect the module for any transit damage or contamination on the mating surfaces of the connectors.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the Fieldbus Box using the integrated mounting holes. The installation position is variable, but select an orientation that minimizes mechanical strain on connected cables.\u003c\/li\u003e\n  \u003cli\u003eConnect the fieldbus line using the M12 B-coded connector, ensuring correct torque is applied to maintain the IP rating.\u003c\/li\u003e\n  \u003cli\u003eWire the 24 V DC control voltage supply to the M8 feed connector. If connecting multiple boxes in series, route downstream power from the corresponding M8 female socket.\u003c\/li\u003e\n  \u003cli\u003eSet the node address using the physical address selection switches on the module, or configure via the KS2000 configuration software interface.\u003c\/li\u003e\n  \u003cli\u003eApply power and perform system diagnostics to verify active communication with the master controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106448433515,"sku":"IP3202-B730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3202-b730-loolm4enilo.png?v=1776245089","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip3202-b730-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}