{"product_id":"beckhoff-ip3312-b200-fieldbus-box","title":"BECKHOFF IP3312-B200 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP3312-B200 is a modular Fieldbus Box designed for decentralized industrial automation tasks. This device integrates directly into harsh industrial environments without requiring a control cabinet, utilizing a high protection rating to ensure reliable operation close to the machine level. As part of the BECKHOFF decentralized I\/O product range, it processes peripheral signals and communicates over a specific fieldbus interface, providing flexible signal collection and distribution for automated manufacturing and process systems.\u003c\/p\u003e\n\u003cp\u003eEngineered for decentralized machine architectures, the unit connects local digital or analog peripheral signals and interfaces directly with higher-level control systems via fiber-optic communication lines. The IP3312-B200 supports configuration via the KS2000 software tool or directly through the connected controller, allowing efficient setup and diagnostic management in distributed topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized Fieldbus Box architecture designed for machine-level installation without control cabinets\u003c\/li\u003e\n  \u003cli\u003eBus interface featuring two fiber-optic sockets for robust data transmission\u003c\/li\u003e\n  \u003cli\u003eData transfer rate of 2.5 Mbaud\u003c\/li\u003e\n  \u003cli\u003eConfigurable via the KS2000 software configuration tool or the master controller\u003c\/li\u003e\n  \u003cli\u003eControl voltage supply rated at 24 V DC with reverse polarity protection tolerances\u003c\/li\u003e\n  \u003cli\u003eM8 connector layout for power supply feed and downstream power connections\u003c\/li\u003e\n  \u003cli\u003eHigh environmental protection rating suitable for demanding industrial conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized signal acquisition and control in automated manufacturing lines\u003c\/li\u003e\n  \u003cli\u003eMachine-mounted industrial automation systems requiring cabinet-free I\/O distribution\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems utilizing fiber-optic network topologies\u003c\/li\u003e\n  \u003cli\u003eSpecial-purpose machinery requiring high dust and moisture resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP3312-B200\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExtension Modules\u003c\/td\u003e\n      \u003ctd\u003eNot applicable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eCommunication and Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e2 x fiber-optic socket for plug ZS1020-0010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e2.5 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Possibility\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 or the controller\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Characteristics\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Power Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage Power Supply\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection (Feed)\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection (Downstream)\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: yes; control voltage\/inputs or outputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 250 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eVerify that the exact model IP3312-B200 matches your system requirements and physical mounting layout.\u003c\/li\u003e\n  \u003cli\u003eEnsure all power supplies and connected circuits are fully de-energized before mounting or wiring the device.\u003c\/li\u003e\n  \u003cli\u003eInspect the module, M8 connectors, and fiber-optic sockets for any physical damage or contamination.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a flat machine surface in a variable installation position appropriate for the application.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage supply to the M8 male feed socket and link downstream devices using the M8 female socket as needed.\u003c\/li\u003e\n  \u003cli\u003eAttach the fiber-optic communication lines using compatible ZS1020-0010 plugs to establish the network connection.\u003c\/li\u003e\n  \u003cli\u003eCheck all potential relationships, signal wiring, and grounding integrity before restoring power to the system.\u003c\/li\u003e\n  \u003cli\u003ePower on the control system and configure the device parameters via the KS2000 software or master controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106427724139,"sku":"IP3312-B200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3312-b200-l0wdfqfmdfk.png?v=1776245090","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip3312-b200-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}