{"product_id":"beckhoff-ip3312-b510-fieldbus-box","title":"BECKHOFF IP3312-B510 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP3312-B510 Fieldbus Box is a decentralised industrial automation device designed for harsh industrial environments requiring high protection ratings. Operating as a CANopen fieldbus node, this unit facilitates reliable data communication and connects peripheral signals directly at the machine level without requiring a control cabinet.\u003c\/p\u003e\n\u003cp\u003eEquipped with an integrated CANopen interface, the device supports automatic baud rate detection from 10 kbaud up to 1 Mbaud, along with extensive communication features including process data objects, node guarding, emergency objects, and variable mapping. Its robust IP65, IP66, and IP67 construction ensures reliable performance under demanding conditions involving moisture, dust, and mechanical stress.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated CANopen bus interface with a 5-pin M12 plug connection\u003c\/li\u003e\n  \u003cli\u003eAutomatic data transfer rate detection from 10 kbaud up to 1 Mbaud\u003c\/li\u003e\n  \u003cli\u003eSupports up to 16 send and 16 receive CANopen process data objects (PDOs)\u003c\/li\u003e\n  \u003cli\u003eConfigurable via the KS2000 software tool or through the controller using service data objects (SDOs)\u003c\/li\u003e\n  \u003cli\u003eRugged decentralized IP65\/IP66\/IP67 housing for direct machine-level mounting\u003c\/li\u003e\n  \u003cli\u003eFlexible I\/O communication types including event-driven, cyclic, synchronous, and polling modes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized machine automation without control cabinets\u003c\/li\u003e\n  \u003cli\u003eConveyor and material handling systems exposed to dust and moisture\u003c\/li\u003e\n  \u003cli\u003eCANopen-based industrial machinery and production lines\u003c\/li\u003e\n  \u003cli\u003eHarsh manufacturing environments requiring high ingress protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eIP3312-B510\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection of 10 kbaud up to 1 Mbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable (2 x signal, 1 x CAN ground recommended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of PDOs (CANopen)\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive process data objects\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAdditional CANopen Features\u003c\/td\u003e\n      \u003ctd\u003eLife guarding, node guarding, emergency object, variable mapping, store\/restore\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Possibility\u003c\/td\u003e\n      \u003ctd\u003eThrough KS2000 or the controller (service data objects)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors, max. 0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (control voltage \/ fieldbus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Communication Types\u003c\/td\u003e\n      \u003ctd\u003eEvent-driven, cyclic, synchronous, polling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM12 Plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eCANopen Bus Interface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Male Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower Supply Feed (Control and Load Voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eM8 Female Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eDownstream Power Supply Connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system is completely de-energized before beginning installation or wiring work.\u003c\/li\u003e\n  \u003cli\u003eVerify that the exact model code and supply voltages match system requirements.\u003c\/li\u003e\n  \u003cli\u003eMount the Fieldbus Box securely onto a flat machine surface using appropriate hardware in a variable position suitable for the application.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control voltage supply to the M8 male socket feed.\u003c\/li\u003e\n  \u003cli\u003eConnect the shielded copper cable for the CANopen bus to the 5-pin M12 plug interface, ensuring proper grounding of the CAN ground.\u003c\/li\u003e\n  \u003cli\u003eEstablish signal connections according to the specific peripheral I\/O requirements.\u003c\/li\u003e\n  \u003cli\u003ePerform a complete inspection of all connections and verify communication parameters before re-energizing the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106448007531,"sku":"IP3312-B510","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3312-b510-a1m31acuh01.png?v=1776245091","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip3312-b510-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}