{"product_id":"beckhoff-ip5009-b400-interbus-fieldbus-box-ssi-encoder-interface","title":"BECKHOFF IP5009-B400 Interbus Fieldbus Box SSI Encoder Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP5009-B400\u003c\/strong\u003e is an Interbus-compatible Fieldbus Box module designed to establish a direct connection to absolute SSI encoders. Acting as a single-channel sensor interface, this module reads physical position information from absolute sensors and transmits the data directly to the higher-level Interbus system. Encased in a rugged polyamide XXL housing, this unit is engineered for direct installation on machinery and equipment, eliminating the need for a separate electrical enclosure.\u003c\/p\u003e\n\u003cp\u003eThe module is equipped with a high-speed RS485 difference signal interface capable of processing adjustable serial input lengths. Connection terminals include standardized M23 circular connectors for the absolute encoder and the Interbus network, coupled with compact M8 connectors for power routing. These robust physical connections ensure reliable communication and high ingress protection in industrial automation environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-channel SSI absolute encoder interface for high-precision position feedback\u003c\/li\u003e\n  \u003cli\u003eDirect connection to Interbus networks using standardized M23 circular connections\u003c\/li\u003e\n  \u003cli\u003eRS485 difference signal input for reliable data transmission in electrically noisy environments\u003c\/li\u003e\n  \u003cli\u003eConfigurable SSI data transfer rates with a standard default of 250 kHz\u003c\/li\u003e\n  \u003cli\u003eShort-circuit protected sensor power supply sourced directly from the control voltage\u003c\/li\u003e\n  \u003cli\u003eDurable polyamide housing providing IP65, IP66, and IP67 level protection\u003c\/li\u003e\n  \u003cli\u003eCompatible with the BECKHOFF KS2000 software suite for simplified parameters setup and diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect machine-mounted absolute position monitoring without protective control cabinets\u003c\/li\u003e\n  \u003cli\u003eRotary and linear encoder integration in Interbus-based factory automation\u003c\/li\u003e\n  \u003cli\u003eIndustrial motion control, material handling, and conveyor systems requiring absolute position feedback\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP5009-B400\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 350 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Mounting\u003c\/td\u003e\n      \u003ctd\u003e2 x 3.5 mm diameter fixing holes for M3 screws\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Power Supply\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (20...29 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e85 mA + sensor current consumption (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSensor Supply\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A, short-circuit proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEncoder Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC, from load voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eInterbus and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus System\u003c\/td\u003e\n      \u003ctd\u003eInterbus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M23 female socket (9-pin), 1 x M23 male socket (9-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rate (Bus)\u003c\/td\u003e\n      \u003ctd\u003e500 kBaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of I\/O Stations\u003c\/td\u003e\n      \u003ctd\u003eDependent on the master (max. 256)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eLiYCY 3 x 2 x 0.22 mm² cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003eMax. 400 m between modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSSI Interface\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSSI Encoder Connection\u003c\/td\u003e\n      \u003ctd\u003eM23 connector with outer thread, 12-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Input\u003c\/td\u003e\n      \u003ctd\u003eDifference signal (RS485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSSI Data Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eVariable up to 1 MHz (250 kHz default)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSerial Input\u003c\/td\u003e\n      \u003ctd\u003e24 bits (adjustable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Direction\u003c\/td\u003e\n      \u003ctd\u003eRead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003eInput: 1 x 32-bit data (optional 1 x 8-bit control\/status)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Safety standards\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration and Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity and Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the system power supply is completely switched off and locked out prior to commencing installation.\u003c\/li\u003e\n  \u003cli\u003eInspect the \u003cstrong\u003eBECKHOFF IP5009-B400\u003c\/strong\u003e Fieldbus Box for any physical damage before mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the module directly to a flat, vibration-free mounting surface using the two integrated 3.5 mm holes and appropriate M3 hardware.\u003c\/li\u003e\n  \u003cli\u003eConnect the 12-pin M23 SSI encoder cable to the matching threaded connector on the module, ensuring the outer ring is fully tightened to maintain environmental integrity.\u003c\/li\u003e\n  \u003cli\u003eConnect the Interbus input and output network cables to the M23 9-pin connections.\u003c\/li\u003e\n  \u003cli\u003ePlug in the 4-pin M8 power connections, verifying correct polarity for both control and load voltages.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and observe the status LEDs to verify proper operation and interface communication.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eConfiguration Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo configure operational parameters such as the SSI transfer rate or serial input bit width, connect the \u003cstrong\u003eBECKHOFF IP5009-B400\u003c\/strong\u003e to a PC running the BECKHOFF KS2000 configuration software tool. Within the software interface, you can adjust the process image mapping and set the module properties according to the exact specifications of the connected absolute encoder.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106427855211,"sku":"IP5009-B400","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5009-b400-qsg0gecrl30.png?v=1776245104","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip5009-b400-interbus-fieldbus-box-ssi-encoder-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}