{"product_id":"beckhoff-ip5109-b528-devicenet-fieldbus-box","title":"BECKHOFF IP5109-B528 DeviceNet Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF IP5109-B528 is a fieldbus-level communication module designed for direct mounting on machinery and equipment. Utilizing the DeviceNet protocol, this Fieldbus Box allows for highly distributed control layouts, collecting and transmitting peripheral signals directly at the machine site without requiring a protective control cabinet.\u003c\/p\u003e\n\n\u003cp\u003eThe BECKHOFF IP5109-B528 features integrated physical connections, utilizing an M12 plug and socket arrangement with an integrated tee-connector to simplify network topology. Transmission rates are detected automatically up to a maximum of 500 kbaud, matching the configured speed of the local DeviceNet segment. Electrical isolation of 500 V between the control logic and the fieldbus network ensures safe, stable signal transfer even in electrically noisy industrial environments.\u003c\/p\u003e\n\n\u003cp\u003ePower delivery is split into distinct paths to maintain operational security, with control and load voltages configured via M8 supply connectors. Highly durable and protective housings make this device suitable for wet, dusty, or mechanically demanding environments, providing reliable signal integration directly at the point of action.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDeviceNet network communication with automatic transmission rate detection up to 500 kbaud\u003c\/li\u003e\n  \u003cli\u003eIntegrated physical bus interface consisting of one M12 plug (5-pin) and one M12 socket (5-pin) featuring a built-in tee-connector\u003c\/li\u003e\n  \u003cli\u003eSeparate 24 V DC control voltage input and load voltage supply lines to isolate logical operations from field loads\u003c\/li\u003e\n  \u003cli\u003eFlexible I\/O communication options, supporting polling, bit strobe, cyclic, and change-of-state modes\u003c\/li\u003e\n  \u003cli\u003eDirect machine mounting capability supported by a highly protective IP65, IP66, and IP67-rated enclosure\u003c\/li\u003e\n  \u003cli\u003eConfiguration options using the KS2000 software interface or direct controller-level explicit messaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDecentralized signal processing in high-moisture or washdown-heavy environments\u003c\/li\u003e\n  \u003cli\u003eDistributed machinery architectures using DeviceNet fieldbus topologies\u003c\/li\u003e\n  \u003cli\u003eModular production lines requiring on-machine mounting without external electrical enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eIP5109-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eFieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration Option\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software or the controller (explicit messaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eFieldbus and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFieldbus Protocol\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Interface\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin), integrated tee-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Medium\u003c\/td\u003e\n      \u003ctd\u003eShielded copper cable, with power supply, typically 2 x 2 x 0.25 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Communication Types\u003c\/td\u003e\n      \u003ctd\u003eBit strobe, polling, cyclic, change of state\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical Data\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eControl Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Voltage Supply\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBox Supply Current\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current consumption (maximum 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAuxiliary Power Current\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003eControl voltage to fieldbus: 500 V; Control voltage to inputs\/outputs: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eParameter\u003c\/td\u003e\n      \u003ctd\u003eSpecification\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 degC to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that all power sources (control and load voltages) are completely de-energized before mounting, wiring, or servicing the unit.\u003c\/li\u003e\n  \u003cli\u003eInspect the physical housing of the device for any structural damage before installation.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely on a flat machine surface using the designated mounting holes. Variable orientation is permitted.\u003c\/li\u003e\n  \u003cli\u003eConnect the DeviceNet network cabling to the M12 connectors, ensuring the integrated tee-connector configuration matches your network loop requirements.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC control power and downstream power loop via the integrated 4-pin M8 connectors, paying close attention to correct pin assignments.\u003c\/li\u003e\n  \u003cli\u003eEnsure all unused M12 and M8 ports are sealed with appropriate protective caps to maintain the IP65\/66\/67 environmental protection rating.\u003c\/li\u003e\n  \u003cli\u003ePerform configuration tasks using the KS2000 tool or direct explicit messaging via your master controller.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cp\u003eWhen replacing an existing unit with a new BECKHOFF IP5109-B528, record all physical wiring connections, device node addressing, and network baud rate configurations beforehand. Switch off all control and load power supplies. Swap the physical unit and reconnect the M12 and M8 cables, securing the connections tightly to preserve environmental sealing. Verify node configuration and run system checks to confirm correct network communication and status led behaviors before resuming automated operations.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106433327467,"sku":"IP5109-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5109-b528-dyoljao1vfw.png?v=1776245111","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip5109-b528-devicenet-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}