{"product_id":"beckhoff-ip6002-b810-fieldbus-box","title":"BECKHOFF IP6002-B810 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF IP6002-B810\u003c\/strong\u003e is a rugged, decentralized Fieldbus Box designed for direct machine installation without a protective control cabinet. Utilizing an open, documented serial transmission protocol, this module facilitates direct communication with digital and analog peripheral signals. It acts as an integration point for distributed machine installations, providing reliable data handling and high environmental protection.\u003c\/p\u003e\n\u003cp\u003eThe device features an integrated RS485 communication interface routed through a robust 5-pin, B-coded M12 connector. Parameterization, diagnosis, and configuration of the module are handled through the standard BECKHOFF KS2000 software tool, allowing simple integration into existing setups. To streamline installation, the module includes standardized M8 power connections, providing a secure feed and an integrated downstream loop for daisy-chaining power to adjacent modules.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eImplements an open, fully documented serial communication protocol for wide system compatibility.\u003c\/li\u003e\n  \u003cli\u003eFeatures a single 5-pin, B-coded M12 socket for the primary bus interface connection.\u003c\/li\u003e\n  \u003cli\u003eCompatible with the BECKHOFF KS2000 software tool for straightforward software configuration.\u003c\/li\u003e\n  \u003cli\u003eEquipped with M8 4-pin electrical interfaces for both input power feed and downstream distribution.\u003c\/li\u003e\n  \u003cli\u003eProvides internal electrical isolation between the control voltage and the fieldbus network.\u003c\/li\u003e\n  \u003cli\u003eBoasts an IP65, IP66, and IP67-rated enclosure, allowing variable installation positions directly on machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eControl-cabinet-free distributed industrial automation and data collection.\u003c\/li\u003e\n  \u003cli\u003eDecentralized signal routing on packaging systems, material handling machinery, and conveyor networks.\u003c\/li\u003e\n  \u003cli\u003eHarsh operating environments requiring direct-mount, high-protection class fieldbus nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP6002-B810\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eExtension Modules\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConfiguration Possibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVia KS2000 software\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical and Signals\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLoad Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Peripheral Signals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAnalog Peripheral Signals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAuxiliary Power Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAccording to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: Yes; Control voltage\/I\/O: According to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eInterfaces and Connections\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Downstream Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female connector, 4-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 210 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInstallation Position\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity \/ Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApprovals and Markings\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE, UL\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure that the power supply to the entire automation system is fully de-energized before mounting.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely using the designated integrated mounting holes on the machine frame in a variable, application-appropriate position.\u003c\/li\u003e\n  \u003cli\u003eConnect the fieldbus communication cable to the B-coded 5-pin M12 socket, ensuring the plug is properly seated to preserve the ingress protection rating.\u003c\/li\u003e\n  \u003cli\u003eProvide the 24 V DC control voltage to the M8 4-pin male feed port. If routing power to subsequent modules, connect the M8 female downstream port to the next unit.\u003c\/li\u003e\n  \u003cli\u003ePerform configuration and commissioning parameters within the KS2000 environment.\u003c\/li\u003e\n  \u003cli\u003eEnergize the system and verify standard operational diagnostics via the system status indicators.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451644779,"sku":"IP6002-B810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip6002-b810-bjisefgvl45.png?v=1776245119","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ip6002-b810-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}