{"product_id":"beckhoff-kl3042-bus-terminal","title":"Beckhoff KL3042 Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing analog input signals within the Beckhoff I\/O system, the \u003cstrong\u003eBECKHOFF KL3042\u003c\/strong\u003e Bus Terminal features two channels designed to acquire standard industrial currents ranging from 0 to 20 mA. This 12-bit resolution terminal operates on a single-ended technology scheme, providing highly reliable communication to the upper-level K-bus. By integrating an onboard sensor supply, this device minimizes the need for external distribution terminals, streamlining cabinet wiring in space-constrained industrial installations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eTwo single-ended analog input channels for standard current-loop signals\u003c\/li\u003e\n  \u003cli\u003e12-bit digitization resolution for precise monitoring of process variables\u003c\/li\u003e\n  \u003cli\u003eIntegrated sensor supply connection points routing 24 V DC directly to field transmitters\u003c\/li\u003e\n  \u003cli\u003eHigh-speed conversion timing optimizing PLC cycle responsiveness\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm housing width maximizing DIN-rail spatial density\u003c\/li\u003e\n  \u003cli\u003eGalvanic isolation rated at 500 V protecting the internal K-bus architecture\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eContinuous process monitoring (flowmeters, pressure transducers, level indicators)\u003c\/li\u003e\n  \u003cli\u003eHVAC environmental monitoring and pneumatic damper positioning systems\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater municipal pump control panels\u003c\/li\u003e\n  \u003cli\u003eFactory automation machinery utilizing standard 0 to 20 mA loop transmitters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eKL Bus Terminal Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSignal Current Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 20 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e12-bit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTechnology Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSingle-ended\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInternal Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e80 ohms + diode voltage 0.7 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConversion Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eapprox. 2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMeasurement Uncertainty\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e\u0026lt; +\/-0.3 percent (relative to full scale value)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSurge Voltage Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003emax. 35 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCurrent Consumption (K-bus)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003etyp. 65 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProcess Image Bit Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInput: 2 x 16-bit data (2 x 8-bit control\/status optional)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e95 percent, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20 (variable installation position)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eApprovals \u0026amp; Markings\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE, UL, ATEX, IECEx, DNV GL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEx Marking\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eATEX: II 3 G Ex ec IIC T4 Gc \/ IECEx: Ex ec IIC T4 Gc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.07 kg (exclusive of protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eTerminal Connection Point\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAnalog Input 1 (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSensor Supply 1 (+24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 V Sensor Supply (connected internally with point 7)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eShield \/ Functional Earth (PE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eAnalog Input 2 (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e6\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSensor Supply 2 (+24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 V Sensor Supply (connected internally with point 3)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eShield \/ Functional Earth (PE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFor installations requiring fast-disconnect options or pre-wired cable harnesses, transition to the \u003cstrong\u003eKS3042\u003c\/strong\u003e model, which features pluggable connection blocks with identical technical ratings. Ensure the K-bus coupler (e.g., BK9000 or BK1100) firmware is up to date to properly map the 2 x 16-bit process image in your TwinCAT System Manager software configuration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this is a \u003cstrong\u003esingle-ended\u003c\/strong\u003e input card, all channels share an internal common reference point. Connecting loop transmitters that have distinct, non-isolated grounds can generate ground-loop currents, resulting in measurement deviations or card errors. If utilizing active, externally powered 4-wire transmitters, ensure the loop signal remains isolated or shares a common 0 V DC potential with the cabinet supply bus.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways route current loop cabling using shielded, twisted-pair lines. Terminate the shield directly to connections 4 and 8 (PE) at the terminal, or land them on an auxiliary shield clamp bus bar positioned directly at the entry of the control panel to minimize electromagnetic interference from neighboring variable frequency drives.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; color: #9b2c2c; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize all primary and auxiliary power contacts before inserting or removing any Bus Terminals from the node segment. Failure to do so can cause electric arcing, leading to physical damage to the internal K-bus contacts and system communications failure.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the bus coupler on a standard 35 mm DIN rail (EN 60715) and lock it into place using the integrated rail clamp.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the module along the guide slot of the adjacent terminal until the tongue-and-groove joint is fully locked.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003ePress the module firmly against the DIN rail until the side latching mechanism clicks, indicating secure grounding contact.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; margin-right: 10px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eUsing a standard flat-head screwdriver, insert wire leads into the tension clamp connection points and release the spring mechanism to complete the connection.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106498765163,"sku":"KL3042","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl3042-gaze4wn0rxd.png?v=1776245152","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-kl3042-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}