{"product_id":"beckhoff-kl6224-io-link-master-bus-terminal","title":"BECKHOFF KL6224 IO-Link Master Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF KL6224\u003c\/strong\u003e is an IO-Link master Bus Terminal designed to integrate field-level IO-Link devices directly into the standard K-bus terminal system. Operating as a point-to-point interface, this terminal enables the integration of up to four IO-Link devices, including intelligent sensors, actuators, or specialty modules. This integration facilitates bidirectional communication, allowing the controller level to access process data, parameter configurations, and comprehensive diagnostic information.\u003c\/p\u003e\n\n\u003cp\u003eUtilizing a compact 12 mm housing, the \u003cstrong\u003eBECKHOFF KL6224\u003c\/strong\u003e supports a 3-wire connection method for efficient field wiring. The terminal accommodates variable communication speeds and acts as a gateway between the field devices and the higher-level automation bus network. This enables predictive maintenance, parameter storage, and real-time device monitoring within standard K-bus configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour independent IO-Link channels for connection of up to four IO-Link field devices\u003c\/li\u003e\n  \u003cli\u003eFull compliance with the IO-Link specification V1.1\u003c\/li\u003e\n  \u003cli\u003eSupports standard transmission rates of 4.8 kbaud, 38.4 kbaud, and 230.4 kbaud\u003c\/li\u003e\n  \u003cli\u003e3-wire connection technology for straightforward wiring topologies\u003c\/li\u003e\n  \u003cli\u003eStandard 500 V electrical isolation between K-bus and signal voltage levels\u003c\/li\u003e\n  \u003cli\u003eIntegral diagnostic status LEDs for individual channel monitoring\u003c\/li\u003e\n  \u003cli\u003eSaves cabinet space with a compact, DIN rail-mountable housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegration of intelligent sensors and actuators into K-bus control architectures\u003c\/li\u003e\n  \u003cli\u003eAutomated parameters mapping and recipe distribution to field-level components\u003c\/li\u003e\n  \u003cli\u003eMachine diagnostic networks requiring device-specific health and error monitoring\u003c\/li\u003e\n  \u003cli\u003eFactory automation environments utilizing standardized IO-Link topologies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eKL6224\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal (IO-Link Master)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eapprox. 60 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003eVia K-bus and power contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption (K-bus)\u003c\/td\u003e\n      \u003ctd\u003etyp. 85 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Contacts\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eIO-Link and Communication\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSpecification Version\u003c\/td\u003e\n      \u003ctd\u003eIO-Link V1.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Method\u003c\/td\u003e\n      \u003ctd\u003e3-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eData Transfer Rates\u003c\/td\u003e\n      \u003ctd\u003e4.8 kbaud, 38.4 kbaud, and 230.4 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Length\u003c\/td\u003e\n      \u003ctd\u003emax. 20 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the power supply to the entire K-bus assembly is switched off before inserting or removing any terminal block.\u003c\/li\u003e\n  \u003cli\u003eInspect the \u003cstrong\u003eBECKHOFF KL6224\u003c\/strong\u003e for physical damage prior to installation on the mounting rail.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal on a standard 35 mm DIN rail, pushing it firmly into place until the locking mechanism clicks securely.\u003c\/li\u003e\n  \u003cli\u003eAlign and lock the terminal into the adjacent Bus Terminals to ensure proper contact of K-bus interfaces and power contacts.\u003c\/li\u003e\n  \u003cli\u003eConnect field cables to the designated terminal contact points using the proper 3-wire termination procedure. Do not exceed the maximum IO-Link cable length of 20 meters.\u003c\/li\u003e\n  \u003cli\u003eReapply power to the system and configure the master node settings using the appropriate engineering environment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106527207787,"sku":"KL6224","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl6224-h3jl5wfl2jk.png?v=1776245209","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-kl6224-io-link-master-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}