{"product_id":"beckhoff-kl8001-bus-terminal-power-terminal-for-siemens-contactor","title":"BECKHOFF KL8001 Bus Terminal Power Terminal for Siemens Contactor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegrating electronic motor protection directly into the modular I\/O system, the \u003cstrong\u003eBECKHOFF KL8001\u003c\/strong\u003e operates as an intelligent power terminal interface designed specifically for \u003cstrong\u003eSiemens Sirius 3R contactors\u003c\/strong\u003e (switch size S00, Type 3RT 10 1). This integration allows direct connection and control of up to ten power terminals (at a typical current consumption of 140 mA per contactor) while transmitting comprehensive diagnostics back to the K-bus.\u003c\/p\u003e\n\n\u003cp\u003eThe module facilitates precise measurement of critical electrical parameters including operational current, voltage, and power. It features adjustable nominal current settings ranging from 0.9 A to 9.9 A and selectable tripping classes (5, 10, 15, 20, 25, 30) to protect machinery against overload conditions. Connection to the primary fieldbus system is completed through the \u003cstrong\u003eKL9060\u003c\/strong\u003e adapter terminal, ensuring seamless integration into PLC control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration with Siemens Sirius 3R (size S00) contactor series.\u003c\/li\u003e\n  \u003cli\u003eConfigurable tripping classes ranging from Class 5 to Class 30.\u003c\/li\u003e\n  \u003cli\u003eReal-time monitoring of current, voltage, and power parameters.\u003c\/li\u003e\n  \u003cli\u003eFlexible parameterization via KS2000 software, fieldbus control, or manual settings.\u003c\/li\u003e\n  \u003cli\u003eHigh short-circuit resistance up to 5 kA conforming to EN 60947-4-1.\u003c\/li\u003e\n  \u003cli\u003eRobust K-bus electrical isolation protecting controller electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMotor control centers (MCC) in process industries.\u003c\/li\u003e\n  \u003cli\u003eAutomated conveyor lines and material handling systems.\u003c\/li\u003e\n  \u003cli\u003ePumping stations and industrial ventilation control.\u003c\/li\u003e\n  \u003cli\u003eHeavy machinery manufacturing and assembly lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKL8001\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal System (K-bus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupported Contactor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSiemens Sirius 3R (Size S00, Type 3RT 10 1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Number of Power Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 10 (at typ. 140 mA per contactor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Current Setting Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.9 to 9.9 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTripping Classes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClass 5, 10, 15, 20, 25, 30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasured Values\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCurrent, Voltage, Power\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.1 A AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Load (Fuse)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMax. 25 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Proof\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUp to 5 kA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 1 mOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eK-Bus Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x flat plug socket, 10-pin\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eK-Bus Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp. 150 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Contacts Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTyp. 7 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Contacts Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%), max. 1.4 A (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (24 V DC \/ K-bus), 2500 V (mains supply \/ K-bus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcess Image Bit Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInput\/Output: 64 bits (8-bit control\/status, 32-bit data)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRequired Adapter Terminal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eKL9060\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Circuit Behavior\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60947-4-1 (assignment type 2) \/ VDE 102\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 90 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eTerminal Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Path Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eScrew terminals up to 2 x 2.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eK-Bus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x 10-pin flat plug sockets\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAdapter Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInterface for KL9060 adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMounting is variable and dependent on the connected contactor. Install the unit in a dry, dust-free enclosure rated to at least IP54.\u003c\/li\u003e\n  \u003cli\u003eEnsure proper seating of the 10-pin flat cable to the KL9060 adapter terminal on the K-bus rail.\u003c\/li\u003e\n  \u003cli\u003eObserve maximum wiring capacity of 2.5 mm² for all screw terminal connections to prevent overheating.\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the 25 A maximum fuse limit on the current load path.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eCSA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106528289131,"sku":"KL8001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl8001-ydo2we40kmu.png?v=1776245217","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-kl8001-bus-terminal-power-terminal-for-siemens-contactor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}