{"product_id":"beckhoff-km1012-0001-bus-terminal-16-channel-digital-input-module","title":"Beckhoff KM1012-0001 Bus Terminal 16-Channel Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eInterfacing sixteen 24V DC binary control signals with the central K-bus backplane, the Beckhoff KM1012-0001 compact bus terminal module features a high-density 1-wire pluggable connection interface designed for space-optimized control cabinets. This unit transmits electrically isolated digital inputs directly to the higher-level automation controller, matching the integration workflow of standard Beckhoff K-bus terminal blocks. By incorporating sixteen distinct input channels across two plug-in connectors, this module significantly reduces the required DIN rail footprint while maintaining signal integrity under heavy electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Architecture:\u003c\/strong\u003e Combines 16 digital input channels in a compact 26.5 mm housing, dividing signals into two 8-channel pluggable connector blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient Signal Processing:\u003c\/strong\u003e Hardware-implemented input filter of typically 0.2 ms prevents contact bounce issues and ensures rapid processing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePluggable Wiring Level:\u003c\/strong\u003e Shipped with a pre-configured 1-wire plug-in connector interface, allowing rapid module replacement during maintenance cycles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e Complete 500 V optocoupler isolation between the internal K-bus electronics and the field potential.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow Internal Draw:\u003c\/strong\u003e Draws only 3 mA typical from the internal K-bus supply, minimizing overall cabinet thermal loading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachine Tool Automation:\u003c\/strong\u003e Monitoring limit switches, proximity sensors, and basic pushbuttons.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging and Material Handling:\u003c\/strong\u003e Processing high-volume sensor arrays along conveyor tracks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Assembly Stations:\u003c\/strong\u003e Space-restricted control panels requiring dense digital sensor integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC and Building Controls:\u003c\/strong\u003e Consolidating binary auxiliary contacts and alarm relays into centralized PLC racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eKM1012 Series Variant Directory\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px;\"\u003eOrder Code\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eWiring Configuration\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eStatus LED Indication\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eConnector Status\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eKM1012-0000\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1-wire system\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNot included (Base module only)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eKM1012-0001\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1-wire system\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNo\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1-wire plug connector included\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eKM1012-0002\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1-wire system\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eYes (Integrated LEDs)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1-wire plug connector with LEDs included\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eKM1012-0004\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-wire system\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eYes (Integrated LEDs)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-wire plug connector with LEDs included\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; font-size: 0.9rem;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff Automation GmbH \u0026amp; Co. KG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 (divided into 2 x 8-channel groups)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSignal Voltage (0-state)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-3 V DC to +5 V DC (EN 61131-2, Type 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSignal Voltage (1-state)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15 V DC to 30 V DC (EN 61131-2, Type 1)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Filter Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypically 0.2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Nominal Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypically 5 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCurrent Draw (K-bus)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTypically 3 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCurrent Draw (Power Contacts)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNone (unconnected)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eIsolation Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e500 V RMS (K-bus to field potential)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProcess Image Bit Width\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e16 inputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnection Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePluggable connection level, 1-wire system\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConductor Cross-Section\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.08 mm to 1.5 mm (Solid or stranded wire)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eWire Stripping Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e26.5 mm x 100 mm x 71 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 degC to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 degC to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eRelative Humidity Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e95%, non-condensing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEnvironmental Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27 (Vibration\/Shock)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP20 (with variable installation positioning)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCertifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.25 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e120 mm x 80 mm x 40 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnector Pin Assignment\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left; font-size: 0.9rem;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 8px; width: 25%;\"\u003eTerminal \/ Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; width: 25%;\"\u003eGroup Allocation\u003c\/th\u003e\n        \u003cth style=\"padding: 8px;\"\u003eFunction \/ Signal Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector 1 (Pins 1 - 8)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInput Group A\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Inputs 1 through 8 (Standard 24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eConnector 2 (Pins 1 - 8)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eInput Group B\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Inputs 9 through 16 (Standard 24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe KM1012-0001 ships standard with a 1-wire connection plug-in system. It is fully backwards compatible and interchangeable in TwinCAT configurations with the base model (KM1012-0000) once the corresponding physical plug is connected. If status feedback is required directly on the terminal face, consider upgrading to the KM1012-0002 model, which shares the identical process image and footprint but incorporates inline diagnostic LEDs.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this module utilizes a high-density 1-wire connection scheme, there are no onboard power contacts for sensor supply routing. To connect passive 2-wire or 3-wire field sensors, external potential distribution terminals (such as the Beckhoff KL9184 or KL9187) must be integrated onto the rail. Failing to provide a common ground return to the sensor supply rail will cause floating inputs and intermittent state changes.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen stripping sensor wires, ensure a strict stripping length of 8 mm. Shorter stripping lengths will lead to unreliable connection clamp contacts, triggering sporadic input dropouts, whereas excessively stripped cables pose short-circuit risks in dense plug arrays. Always verify that the plug-in connector is securely latched into the terminal base housing before powering up the K-bus rail.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 0.5rem 0 0 0; color: #9b2c2c; font-size: 0.9rem;\"\u003eDe-energize all primary field power and K-bus backplane power supplies before installing, removing, or wiring the module. Working on live equipment risks critical damage to the backplane communication ICs and may lead to unpredictable system states.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eAlign the module side-by-side with other Bus Terminals on a standard 35 mm DIN rail (EN 60715), utilizing the integrated double slot and key connection system.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003ePush the module back onto the DIN rail until the lock mechanisms on both top and bottom securely click into position.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eWire the 1-wire plug-in connector using solid or stranded wires (0.08 to 1.5 mm²), maintaining an exact stripping length of 8 mm.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748; padding-top: 2px;\"\u003eInsert the pre-wired connector assembly firmly into the terminal face of the module until the side-retaining tabs lock cleanly.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106538578283,"sku":"KM1012-0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KM1012-0001-Beckhoff-Bus-Terminal-module-16-channel-digital-input-24-V-DC-02-ms-1-wire-connector-dogxcu230qt.png?v=1776245242","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-km1012-0001-bus-terminal-16-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}