{"product_id":"beckhoff-km1018-0002-bus-terminal-module","title":"BECKHOFF KM1018-0002 Bus Terminal Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF KM1018-0002 is a high-density, compact Bus Terminal module designed for processing up to 64 digital input signals from the field level within industrial automation environments. By grouping multiple channels into a single highly efficient housing, this terminal module optimizes space utilization within control cabinets while maintaining reliable system integration with standard K-bus I\/O architectures.\u003c\/p\u003e\n\u003cp\u003eThis specific variant, the KM1018-0002, features 1-wire connection technology complete with integrated status LEDs, allowing for localized diagnostics at each of the 64 channel connection points. The control signals are transmitted with electrical isolation from the field potential to the higher-level automation unit, ensuring reliable operation in demanding environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density processing of 64 digital input channels in a single terminal housing.\u003c\/li\u003e\n  \u003cli\u003e1-wire connection technology with integrated diagnostic status LEDs for rapid troubleshooting.\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the K-bus and the field potential.\u003c\/li\u003e\n  \u003cli\u003ePluggable wiring level interface for simplified installation and quick physical replacements.\u003c\/li\u003e\n  \u003cli\u003eCompact design form factor engineered for mounting on standard DIN rails.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-channel count digital signal collection in space-restricted control cabinets.\u003c\/li\u003e\n  \u003cli\u003eIndustrial machine control and localized manufacturing automation setups.\u003c\/li\u003e\n  \u003cli\u003eDistributed I\/O processing integrated with standard Beckhoff K-bus couplers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral and Physical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKM1018-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eCompact terminal module with pluggable wiring level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e123 mm x 100 mm x 55 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 310 g to 390 g depending on connector type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and Electrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e64\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003e1-wire pluggable connector with LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"0\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\"1\" Signal Voltage\u003c\/td\u003e\n      \u003ctd\u003e15 to 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 3 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003e64 inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (stranded or solid wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental and Standards\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degrees Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degrees Celsius\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals and Markings\u003c\/td\u003e\n      \u003ctd\u003eCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem De-energization:\u003c\/strong\u003e Prior to starting any installation, mounting, or wiring procedures, isolate and switch off the power supply to the entire control cabinet.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Securely clip the terminal block onto a standard 35 mm DIN rail (EN 60715) using the integrated lock system. Ensure a rigid mechanical fit using the double slot and key connection for side-by-side assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring and Connectors:\u003c\/strong\u003e Strip input conductors to a length of 8 mm. Insert wires ranging from 0.08 to 1.5 mm² into the pluggable 1-wire connector block.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStatus Check:\u003c\/strong\u003e Restore system power and observe the channel-specific status LEDs to confirm logical status changes of the 64 input signals during commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106461344107,"sku":"KM1018-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KM1018-0002-Beckhoff-Bus-Terminal-module-64-channel-digital-input-24-V-DC-3-ms-1-wire-connector-with-LEDs-lyvuihltvso.png?v=1776245250","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-km1018-0002-bus-terminal-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}