{"product_id":"beckhoff-km2008-0002-bus-terminal-module","title":"BECKHOFF KM2008-0002 Bus Terminal Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF KM2008-0002\u003c\/strong\u003e is a high-density Bus Terminal module featuring 64 digital outputs designed for integration within the BECKHOFF I\/O system. This compact terminal module transfers binary control signals from the automation controller, providing electrically isolated switching for actuators at the process level. Featuring a pluggable wiring level, it organizes channels into eight groups of eight via multi-pin connectors.\u003c\/p\u003e\n\u003cp\u003eThis specific variant, the KM2008-0002, is supplied with a 1-wire connector and integrated diagnostic LEDs to indicate channel status clearly. It handles 24 V DC signals with a maximum output current of 0.5 A per channel and incorporates short-circuit proof protection. The unit communicates via the K-bus and occupies 64 bits in the process image.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e64 digital output channels arranged in an 8 x 8 connector architecture\u003c\/li\u003e\n  \u003cli\u003eEquipped with a 1-wire connector and integrated diagnostic LEDs for clear status visibility\u003c\/li\u003e\n  \u003cli\u003eNominal voltage of 24 V DC with a max output current of 0.5 A per channel\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof channels with integrated reverse voltage protection\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the K-bus and field potential\u003c\/li\u003e\n  \u003cli\u003eCompact terminal module design with a pluggable wiring level for streamlined installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density digital signal switching in machine building and factory automation\u003c\/li\u003e\n  \u003cli\u003eControl of ohmic, inductive, and lamp loads in centralized control cabinets\u003c\/li\u003e\n  \u003cli\u003eIndustrial processes requiring extensive binary actuator control within limited DIN rail space\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eModel \/ Variant\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eKM2008-0002\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal module, 64-channel digital output, 24 V DC, 0.5 A, supplied with 1-wire connector and LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKM2008-0000\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal module without connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKM2008-0001\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal module with 1-wire connector (without LEDs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eKM2008-0004\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal module with 3-wire connector and LEDs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKM2008-0002\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eCompact terminal module with pluggable wiring level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e64 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e64 (8 x 8 channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Type\u003c\/td\u003e\n      \u003ctd\u003eOhmic, inductive, lamp load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A per channel (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Current\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBreaking Energy\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 150 mJ\/channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eReverse Voltage Protection\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ field potential)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eNone (no power contacts)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection and Mechanical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003ePlug (1-wire connector included)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (stranded wire, solid wire)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e123 mm x 100 mm x 55 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 310 g (with 1-pin connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation\u003c\/td\u003e\n      \u003ctd\u003eOn 35 mm DIN rail conforming to EN 60715 with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eSide-by-side using double slot and key connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Class\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration\/Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire control system is de-energized and locked out before beginning mechanical or electrical work.\u003c\/li\u003e\n  \u003cli\u003eInspect the BECKHOFF KM2008-0002 terminal module and included connectors for any transport damage.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal module onto a standard 35 mm DIN rail (EN 60715) by snapping it securely into place using the locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eConnect the field wiring to the pluggable 1-wire connector, observing the proper stripping length (8 mm) and conductor cross-sections (0.08 to 1.5 mm²).\u003c\/li\u003e\n  \u003cli\u003ePlug the wired connector securely into the terminal module.\u003c\/li\u003e\n  \u003cli\u003eVerify all process supply voltages, potential assignments, and K-bus connections before restoring power.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and check the integrated diagnostic LEDs to confirm proper operation and signal status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106456723819,"sku":"KM2008-0002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/KM2008-0002-Beckhoff-Bus-Terminal-module-64-channel-digital-output-24-V-DC-05-A-1-wire-connector-with-LEDs-k42cgmi43jk.png?v=1776245264","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-km2008-0002-bus-terminal-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}