{"product_id":"beckhoff-km2652-bus-terminal-module","title":"BECKHOFF KM2652 Bus Terminal Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF KM2652 is a 2-channel digital output Bus Terminal module designed for 230 V AC operation with a maximum output current of 6 A per channel. As part of the established BECKHOFF Bus Terminal system, this module integrates change-over relay contacts and features integrated manual and automatic operation capabilities, allowing direct local control alongside standard controller commands.\u003c\/p\u003e\n\u003cp\u003eThe KM2652 facilitates flexible control and status monitoring in industrial automation architectures. The module provides switch setting readability back to the controller via the process image, reporting the status of hand, auto, and relay ON\/OFF states. It connects to the internal K-bus system for communication with the bus coupler while routing power through associated power contacts.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e2-channel digital output module for 230 V AC applications\u003c\/li\u003e\n  \u003cdiv\u003e\u003c\/div\u003e\n  \u003cli\u003eMaximum output current of 6 A per channel with change-over contact configuration\u003c\/li\u003e\n  \u003cli\u003eIntegrated manual and automatic operation mode selection\u003c\/li\u003e\n  \u003cli\u003eSwitch settings for hand, auto, and relay states readable via the process image\u003c\/li\u003e\n  \u003cli\u003eSupports ohmic, inductive, and lamp loads with electronic ballast compatibility\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting design with IP20 protection rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHVAC and building automation system load switching\u003c\/li\u003e\n  \u003cli\u003eLighting control systems utilizing electronic ballasts\u003c\/li\u003e\n  \u003cli\u003eIndustrial machinery with manual override and local maintenance requirements\u003c\/li\u003e\n  \u003cli\u003eRelay-based actuator control panels requiring feedback on operating modes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKM2652\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e2 x change-over\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Voltage\u003c\/td\u003e\n      \u003ctd\u003e230 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSwitching Voltage Max.\u003c\/td\u003e\n      \u003ctd\u003e250 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMax. Output Current\u003c\/td\u003e\n      \u003ctd\u003e6 A per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSwitching Capacity Max.\u003c\/td\u003e\n      \u003ctd\u003e1.5 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Permitted Load\u003c\/td\u003e\n      \u003ctd\u003e100 mA at 12 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLamp Test \/ Electronic Ballast\u003c\/td\u003e\n      \u003ctd\u003eMax. 10 A starting current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContact Material\u003c\/td\u003e\n      \u003ctd\u003eAgSnO2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 130 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and Process Image\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBit Width in Process Image\u003c\/td\u003e\n      \u003ctd\u003e4 inputs (status hand, auto, relay ON\/OFF), 2 outputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eNo address or configuration setting required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanics and Environment\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Cycles Mech. Min.\u003c\/td\u003e\n      \u003ctd\u003e1 x 10^6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Cycles Electr. Min.\u003c\/td\u003e\n      \u003ctd\u003e1 x 10^5 (3 A \/ 250 V AC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 percent, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInstallation Position\u003c\/td\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApprox. 110 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals\u003c\/td\u003e\n      \u003ctd\u003eCE\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire control system is de-energized and locked out before performing any mechanical or electrical installation work.\u003c\/li\u003e\n  \u003cli\u003eInspect the BECKHOFF KM2652 module for any transit damage or bent pins prior to mounting.\u003c\/li\u003e\n  \u003cli\u003eSnap the Bus Terminal securely onto a standard DIN rail next to the appropriate bus coupler or preceding terminal.\u003c\/li\u003e\n  \u003cli\u003eVerify that power contacts and K-bus connections interlock correctly with adjacent terminals.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the appropriate terminal points according to the designated voltage and load limits, ensuring proper cable shielding and strain relief.\u003c\/li\u003e\n  \u003cli\u003eRestore power and verify module operation, local manual override functions, and process image communication through the control system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106539561323,"sku":"KM2652","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/km2652-odt4pbaix1d.png?v=1776245267","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-km2652-bus-terminal-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}