{"product_id":"beckhoff-ks3464-pluggable-bus-terminal","title":"BECKHOFF KS3464 Pluggable Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF KS3464\u003c\/strong\u003e is a 4-channel analog input Bus Terminal designed to process signals in the range of 0 to 10 V. Housed in a space-saving 12 mm terminal block, it features a specialized pluggable wiring level that allows pre-wired connectors to be easily inserted or removed from the housing, simplifying maintenance and installation processes within K-bus I\/O environments.\u003c\/p\u003e\n\n\u003cp\u003eOperating with single-ended technology, the \u003cstrong\u003eBECKHOFF KS3464\u003c\/strong\u003e maps analog field signals directly to the controller's process image with 12-bit resolution. Power supply for the terminal's internal electronics is drawn directly from the K-bus, with 500 V electrical isolation provided between the K-bus communications and the analog input signals.\u003c\/p\u003e\n\n\u003cp\u003eIts robust construction and mechanical design include a secure double-slot and key interlocking connection for side-by-side mounting on standard 35 mm DIN rails. The terminal represents an efficient, high-density selection for collecting basic analog measurements across varied control architectures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour independent analog inputs for 0 to 10 V signals\u003c\/li\u003e\n  \u003cli\u003eSingle-ended measurement technology referencing a common ground\u003c\/li\u003e\n  \u003cli\u003ePluggable connection technology (KS series) for simplified wiring assembly and swift physical module swaps\u003c\/li\u003e\n  \u003cli\u003e12-bit A\/D conversion resolution\u003c\/li\u003e\n  \u003cli\u003e500 V galvanic isolation between field signal voltage and the internal K-bus\u003c\/li\u003e\n  \u003cli\u003eCompact 12 mm physical width maximizing cabinet space\u003c\/li\u003e\n  \u003cli\u003eDirect integration with standard K-bus terminal systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMonitoring standard 0 to 10 V analog feedback signals from industrial transmitters\u003c\/li\u003e\n  \u003cli\u003eInterfacing with speed, distance, and angle measurement devices\u003c\/li\u003e\n  \u003cli\u003eIntegrating level, pressure, or flow sensors requiring a 0 to 10 V interface\u003c\/li\u003e\n  \u003cli\u003eGeneral manufacturing automation and process machinery control loops\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKS3464\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal (Pluggable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Design\u003c\/td\u003e\n      \u003ctd\u003eTerminal housing with pluggable wiring level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail (EN 60715) with double slot-and-key lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Voltage Range\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Technology\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInternal Resistance\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 130 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e12 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasuring Error\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ±0.3% (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003eInput: 4 x 16 bit data (optional 4 x 8 bit control\/status)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConfiguration\u003c\/td\u003e\n      \u003ctd\u003eNo address or configuration setting required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Source\u003c\/td\u003e\n      \u003ctd\u003eVia the K-bus\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-bus\u003c\/td\u003e\n      \u003ctd\u003eTypically 100 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eMaximum 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Technology\u003c\/td\u003e\n      \u003ctd\u003ePluggable wiring (KS series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eActuation Type\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section (Solid)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (AWG 28 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section (Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm² (AWG 28 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-section (Flexible)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm² (AWG 26 to 16)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003eApproximately 75 g (0.075 kg)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity\/Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power supplies (system power and field power) are disconnected and isolated before handling.\u003c\/li\u003e\n  \u003cli\u003eMount the \u003cstrong\u003eBECKHOFF KS3464\u003c\/strong\u003e onto a standard 35 mm DIN rail (conforming to EN 60715). Align the side-by-side slot-and-key connectors with neighboring terminal modules.\u003c\/li\u003e\n  \u003cli\u003ePrepare field conductors by stripping them to a length of 9 to 10 mm.\u003c\/li\u003e\n  \u003cli\u003eInsert conductors into the correct pluggable connector sockets using a small flat-blade screwdriver to actuate the spring mechanism. Verify correct polarity and wire routing for each single-ended input channel.\u003c\/li\u003e\n  \u003cli\u003ePlug the fully wired connectors securely back into the \u003cstrong\u003eBECKHOFF KS3464\u003c\/strong\u003e terminal block until locked.\u003c\/li\u003e\n  \u003cli\u003eRestore K-bus and system power, and verify proper mapping within the TwinCAT system manager.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBECKHOFF KS3464\u003c\/strong\u003e complies with the following standards and approvals: CE, UL, ATEX, and DNVGL. Ex marking: II 3 G Ex nA IIC T4 Gc.\u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106506170731,"sku":"KS3464","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks3464-vzc5kgzmce5.png?v=1776245309","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ks3464-pluggable-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}