{"product_id":"beckhoff-ks4022-bus-terminal","title":"BECKHOFF KS4022 Bus Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF KS4022 is a two-channel analog output bus terminal designed for the generation of industrial control signals within a modular Bus Terminal system. Utilizing single-ended technology, the terminal converts binary control values from the automation controller into standardized analog process signals. It integrates seamlessly into standard Beckhoff Bus Terminal configurations via the K-bus, communicating process data while providing galvanic isolation between the field level and the internal system bus.\u003c\/p\u003e\n\u003cp\u003eEquipped with pluggable wiring levels, the KS4022 facilitates efficient installation and maintenance by allowing terminal blocks to be disconnected without disturbing the field wiring. This design supports industrial control architectures requiring reliable analog actuation, standard 35 mm DIN rail mounting, and dependable signal conditioning in decentralized automation environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo independent analog output channels with single-ended technology\u003c\/li\u003e\n  \u003cli\u003eStandardized 4 to 20 mA signal current generation for industrial actuators\u003c\/li\u003e\n  \u003cli\u003e12-bit native resolution for precise process control\u003c\/li\u003e\n  \u003cli\u003ePluggable wiring level for all KSxxxx series bus terminals\u003c\/li\u003e\n  \u003cli\u003eK-bus communication interface for data exchange with bus couplers or embedded controllers\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation rated at 500 V between the K-bus and signal voltage\u003c\/li\u003e\n  \u003cli\u003eCompact terminal housing designed for standard 35 mm DIN rail installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial process control systems requiring analog current actuators\u003c\/li\u003e\n  \u003cli\u003eValve positioning and proportional control loops\u003c\/li\u003e\n  \u003cli\u003eSpeed and frequency inverter reference value generation\u003c\/li\u003e\n  \u003cli\u003eDecentralized machine automation utilizing Beckhoff Bus Terminal nodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKS4022\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003eBus Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eTerminal housing with pluggable wiring level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eSignal and I\/O\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTechnology\u003c\/td\u003e\n      \u003ctd\u003eSingle-ended\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Current\u003c\/td\u003e\n      \u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLoad Impedance\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 500 ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e12 bit\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConversion Time\u003c\/td\u003e\n      \u003ctd\u003e~ 1.5 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Error\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; ±0.1 % (relative to end value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProcess Image Bit Width\u003c\/td\u003e\n      \u003ctd\u003eOutput: 2 x 16-bit data (2 x 8-bit control\/status optional)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e24 V DC via power contacts (alternative 15 V DC with power supply terminal KL9515)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eTyp. 50 mA + load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Consumption K-Bus\u003c\/td\u003e\n      \u003ctd\u003eTyp. 60 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n      \u003ctd\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection Technology\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Type\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver (pluggable wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Solid \/ Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section (Fine-Stranded)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConductor Cross-Section AWG\u003c\/td\u003e\n      \u003ctd\u003eAWG 28 to 16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n      \u003ctd\u003e6.8 cm x 1.2 cm x 10.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.08 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003eOn 35 mm DIN rail conforming to EN 60715 with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +60 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-40 to +85 °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 %, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eApprovals and Certifications\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eApprovals \/ Markings\u003c\/td\u003e\n      \u003ctd\u003eCE, UL, ATEX, DNV GL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEx Marking\u003c\/td\u003e\n      \u003ctd\u003eII 3 G Ex nA IIC T4 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure the entire control system is de-energized before performing any mechanical or electrical installation work.\u003c\/li\u003e\n  \u003cli\u003eVerify that the mounting rail is a standard 35 mm DIN rail conforming to EN 60715 and is securely grounded.\u003c\/li\u003e\n  \u003cli\u003eClick the BECKHOFF KS4022 onto the DIN rail next to an appropriate bus coupler, embedded PC, or preceding terminal, utilizing the double slot and key connection for side-by-side alignment.\u003c\/li\u003e\n  \u003cli\u003eConnect field wiring to the pluggable spring-actuated terminals using a suitable screwdriver, ensuring correct conductor stripping lengths of 9 to 10 mm.\u003c\/li\u003e\n  \u003cli\u003eVerify that the 24 V DC power supply to the power contacts and the K-bus connection are correctly established before applying system power.\u003c\/li\u003e\n  \u003cli\u003ePerform a functional check of the analog output signals and process data mapping via the controller engineering software during system commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106490769771,"sku":"KS4022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks4022-qsjo5ehojw1.png?v=1776245316","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ks4022-bus-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}