{"product_id":"beckhoff-ks9508-bus-terminal-power-supply-terminal-8-v-dc","title":"BECKHOFF KS9508 Bus Terminal Power Supply Terminal 8 V DC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe BECKHOFF KS9508 is a Bus Terminal designed to provide a stabilized 8 V DC output voltage within modular I\/O system architectures. Operating on a 24 V DC input voltage, this power supply terminal supplies regulated power to specialized electronic loads and internal bus terminal circuits requiring a tightly controlled 8 V DC supply. It integrates into modular terminal assemblies, featuring pluggable wiring and standard DIN rail mounting.\u003c\/p\u003e\n\u003cp\u003eEquipped with short-circuit protection and a stabilized output, the KS9508 ensures operational safety and voltage integrity for connected field devices. Diagnostic capabilities include an overcurrent LED indicator for status monitoring. The terminal housing is constructed from polycarbonate and supports side-by-side installation alongside other KSxxxx series bus terminals using a double slot and key connection method.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStabilized 8 V DC output voltage with a 1 percent tolerance\u003c\/li\u003e\n  \u003cli\u003eNominal output current capacity of 0.5 A\u003c\/li\u003e\n  \u003cli\u003e24 V DC input voltage range with -15 percent to +20 percent tolerance\u003c\/li\u003e\n  \u003cli\u003eShort-circuit proof output design\u003c\/li\u003e\n  \u003cli\u003eOvercurrent LED indicator for diagnostic status\u003c\/li\u003e\n  \u003cli\u003ePluggable wiring level compatible with KSxxxx Bus Terminals\u003c\/li\u003e\n  \u003cli\u003ePolycarbonate terminal housing design for standard DIN rail installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePower distribution for specialized electronic field devices requiring an 8 V DC supply\u003c\/li\u003e\n  \u003cli\u003eModular industrial automation systems utilizing KSxxxx series bus terminals\u003c\/li\u003e\n  \u003cli\u003eControl cabinet installations requiring isolated or regulated subsidiary voltage levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eExact Model\u003c\/td\u003e\n      \u003ctd\u003eKS9508\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Type\u003c\/td\u003e\n      \u003ctd\u003ePower Supply Terminal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDesign Form\u003c\/td\u003e\n      \u003ctd\u003eTerminal housing with pluggable wiring level\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003ePolycarbonate\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eElectrical\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Voltage\u003c\/td\u003e\n      \u003ctd\u003e8 V DC (+\/- 1 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Current\u003c\/td\u003e\n      \u003ctd\u003e0.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResidual Ripple\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; 5 mV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShort-Circuit Proof\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCurrent Load Power Contacts\u003c\/td\u003e\n      \u003ctd\u003eImax: 10 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eConnection Technology\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWiring Method\u003c\/td\u003e\n      \u003ctd\u003eSpring actuation by screwdriver\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section Solid (s)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section Stranded (st)\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section Fine-Stranded (f)\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Cross-Section AWG\u003c\/td\u003e\n      \u003ctd\u003eAWG 28 to 16 (s, st), AWG 26 to 16 (f)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStripping Length\u003c\/td\u003e\n      \u003ctd\u003e9 to 10 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eMechanical and Environmental\u003c\/h4\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n      \u003ctd\u003e6.8 cm x 1.2 cm x 10.0 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNet Weight\u003c\/td\u003e\n      \u003ctd\u003e0.065 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMounting\u003c\/td\u003e\n      \u003ctd\u003e35 mm DIN rail conforming to EN 60715 with lock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e95 percent, no condensation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n  \u003cli\u003eEnsure all power supplies and field voltage sources are switched off and verified de-energized before beginning installation or wiring work.\u003c\/li\u003e\n  \u003cli\u003eInspect the KS9508 terminal housing and pluggable connectors for any visible transit damage or defects.\u003c\/li\u003e\n  \u003cli\u003eMount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) by snapping it securely into place with the locking mechanism.\u003c\/li\u003e\n  \u003cli\u003eInterlock the terminal side-by-side with adjacent KSxxxx series bus terminals using the double slot and key connection.\u003c\/li\u003e\n  \u003cli\u003eStrip conductors to the specified length of 9 to 10 mm.\u003c\/li\u003e\n  \u003cli\u003eConnect the 24 V DC input supply and output lines using a suitable screwdriver for spring actuation, ensuring secure clamping according to the approved cross-section ranges.\u003c\/li\u003e\n  \u003cli\u003eVerify terminal assignments, potential supply connections, and polarity before restoring power to the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106534383979,"sku":"KS9508","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks9508-1dlxm1il50k.png?v=1776245346","url":"https:\/\/www.plcprotech.com\/products\/beckhoff-ks9508-bus-terminal-power-supply-terminal-8-v-dc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}