{"product_id":"bently-nevada-106m1079-01-3500-15-universal-ac-power-supply-module","title":"Bently Nevada 106M1079-01 3500\/15 Universal AC Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 106M1079-01\u003c\/strong\u003e is a half-height \u003cstrong\u003eUniversal AC Power Supply Module\u003c\/strong\u003e engineered for the 3500 Series Machinery Protection System. This module serves as a primary or redundant power source, converting a broad range of high-voltage alternating current inputs into stable regulated internal voltages required by other monitoring and communication modules in the same rack. It must be installed in designated slots on the left side of the 3500 rack structure, where it can provide full system power independently or run in tandem with a secondary backup power supply without interrupting ongoing machinery protection operations. The \u003cstrong\u003e106M1079-01\u003c\/strong\u003e configuration ensures steady electrical delivery for continuous vibration, position, and speed monitoring functions in critical high-speed rotating industrial machinery setups.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHalf-height module construction optimizing left-side rack slot utilization\u003c\/li\u003e\n\u003cli\u003eSupports full rack power delivery from a single module solution\u003c\/li\u003e\n\u003cli\u003eHot-swappable dual-redundancy architecture permitting live replacement without disrupting operational monitor channels\u003c\/li\u003e\n\u003cli\u003eIntegrated front-panel \"SUPPLY OK\" LED status indicator for immediate technical validation\u003c\/li\u003e\n\u003cli\u003eBroad universal AC input tolerance adapting directly to fluctuating plant electrical grids\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRedundant power distribution for critical 3500 Series Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eContinuous turbine, compressor, and large motor vibration tracking stations\u003c\/li\u003e\n\u003cli\u003eHigh-availability oil, gas, and power generation industrial processing facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106M1079-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal AC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 to 220 Vac nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Non-hazardous areas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 264 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range (Hazardous areas)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 250 Vac rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Peak Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 to 373 Vac pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8 A rms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 Fahrenheit to +150 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 Fahrenheit to +185 Fahrenheit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSUPPLY OK LED indicates when the power supply is operating properly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear PIM Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinks directly to the matching Universal AC Power Input Module (PIM) behind the supply slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation\u003c\/strong\u003e: Ensure the power supply module is inserted exclusively into the half-height slots located on the left side of the 3500 machinery protection rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Setup\u003c\/strong\u003e: When configuring a dual-redundant power setup, install the primary module in the lower slot and the backup module in the upper slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e: Do not attempt to mate the universal AC power supply with legacy High Voltage AC or Low Voltage AC PIMs, as they are completely incompatible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation and Environment\u003c\/strong\u003e: Ensure proper clearance and air cross-flow to maintain ambient operations within the boundaries of -30 degC to +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC\u003c\/strong\u003e: Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives\u003c\/strong\u003e: European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e: European Community Directive: LV Directive 2014\/35\/EU; Standards: EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime\u003c\/strong\u003e: DNV GL rules for classification (Ships, offshore units, high speed\/light craft); ABS Rules for Condition of Classification Part 1, Steel Vessels Rules, Offshore Units and Structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American Hazardous Area Approvals (CNRTLUS)\u003c\/strong\u003e: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx\u003c\/strong\u003e: II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if one power supply fails in a dual-supply system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf two power supplies are installed, the lower module is the primary and the upper is the backup. If one fails, the other automatically maintains full rack operation without any disruption to the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module backwards compatible with older legacy Bently Nevada power inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The universal AC power supply module and its corresponding Power Input Module (PIM) are entirely incompatible with legacy 3500 AC power supplies and legacy PIM components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fuse should be used to protect the associated power entry interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe matching universal AC Power Input Module utilizes a fast-blow replacement fuse rated at 5A\/500 Vac with physical dimensions of 6.3 mm x 32 mm.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666858537323,"sku":"3500\/15 106M1079-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-15-106m1079-01-ac-and-dc-power-supply-okimiqugwsk_3990188f-7544-4ed1-a203-6dac8b418546.jpg?v=1765449241","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-106m1079-01-3500-15-universal-ac-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}