{"product_id":"bently-nevada-125840-02-3500-15-low-voltage-ac-power-input-module","title":"Bently Nevada 125840-02 3500\/15 Low Voltage AC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 125840-02\u003c\/strong\u003e is a \u003cstrong\u003eLow Voltage AC Power Input Module\u003c\/strong\u003e designed for accepting external low-voltage AC line power and interfacing directly with the 3500\/15 AC Power Supply module in the 3500 Machinery Protection System. Operating as a half-height module positioned in the special rear slot directly behind its associated front-installed power supply, the \u003cstrong\u003e125840-02\u003c\/strong\u003e receives line voltage, routes it through an onboard replacement fuse, and routes the conditioned power to the 3500 rack system. It supports a nominal 110 Vac input with an operating range of 85 to 132 Vac rms (and 85 to 125 Vac rms for PIM revisions prior to Rev. R paired with AC Power Supply Modules prior to Rev. M) to power a full rack without requiring a minimum rack load.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpecial half-height rear module mounting positioned directly behind the associated front power supply module\u003c\/li\u003e\n\u003cli\u003eOnboard fuse protection utilizing part number 01720025 replacement fuse\u003c\/li\u003e\n\u003cli\u003eAccepts a nominal input voltage of 110 Vac over an operating range of 85 to 132 Vac rms\u003c\/li\u003e\n\u003cli\u003eAccepts input line frequency from 47 to 63 Hz\u003c\/li\u003e\n\u003cli\u003eSupports primary or redundant power configuration in designated left-side rack slots\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower input interface for Bently Nevada 3500 Series Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eLow-voltage AC main power connection for 3500\/15 AC Power Supply Modules\u003c\/li\u003e\n\u003cli\u003eRotating machinery and turbomachinery condition monitoring installations requiring 110 Vac field power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e125840-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Voltage AC Power Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e127610-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e01720025\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement Fuse (for both AC Power Input Module and High Voltage DC Power Input Modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada \/ GE Measurement \u0026amp; Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125840-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLegacy Low Voltage AC Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 Vac nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 132 Vac rms (120 to 188 Vac pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLegacy Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 125 Vac rms (for PIM prior to Rev. R \/ Power Supply prior to Rev. M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 A rms (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOut of Range Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnder-voltage does not harm the PIM; Over-voltage causes the fuse to open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplacement Fuse Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e01720025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Block Identifier\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLN1\u003c\/td\u003e\n\u003ctd\u003eLine Input Connection 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLN2 \/ NEUT\u003c\/td\u003e\n\u003ctd\u003eLine Input Connection 2 \/ Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGND\u003c\/td\u003e\n\u003ctd\u003eProtective Earth Ground Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the special half-height rear slot located directly behind the associated front 3500\/15 power supply module.\u003c\/li\u003e\n\u003cli\u003eSecure input field wiring to the designated LN1, LN2\/NEUT, and GND screw terminals on the rear terminal strip.\u003c\/li\u003e\n\u003cli\u003eVerify that field voltage is de-energized prior to installing or removing the input wiring and terminal assembly.\u003c\/li\u003e\n\u003cli\u003eEnsure proper insertion of the specified 01720025 replacement fuse into the PIM fuse holder.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e European Community Directive 2014\/30\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety Standard:\u003c\/strong\u003e EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive:\u003c\/strong\u003e European Community Directive 2014\/35\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \/ NRTL\/C (Approval Option 01):\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D; Class I, Zone 2; Ex nC [L] IIC T4 Gc \/ AEx nC IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX \/ IECEx (Approval Option 02):\u003c\/strong\u003e II 3 G, Ex nA nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666846544235,"sku":"125840-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-125840-02-low-voltage-ac-power-input-module-bsopui1o5vn_18aa0739-9677-4d2f-afbc-767e639ec61a.jpg?v=1765448934","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-125840-02-3500-15-low-voltage-ac-power-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}