{"product_id":"bently-nevada-129478-01-high-voltage-dc-power-input-module","title":"Bently Nevada 129478-01 High Voltage dc Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 129478-01\u003c\/strong\u003e High Voltage dc Power Input Module (PIM) is a Power Input Module designed for machinery protection system power distribution. The module is a special half-height rear card located directly behind the associated \u003cstrong\u003e129486-01\u003c\/strong\u003e High Voltage dc Power Supply Module within the \u003cstrong\u003e3500\/15\u003c\/strong\u003e power supply system. It accepts an input voltage of 88 to 140 Vdc, routing power through the internal rack power bus architecture to support machinery monitoring and protection hardware. The module incorporates input fuse protection, where an over-voltage condition causes the fuse to open to protect downstream components, while under-voltage conditions cause no harm to the module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts an input voltage range of 88 to 140 Vdc\u003c\/li\u003e\n\u003cli\u003eMounts directly behind the associated power supply module in a half-height rear slot\u003c\/li\u003e\n\u003cli\u003eContains an integrated over-voltage input fuse protection system\u003c\/li\u003e\n\u003cli\u003eSupports full 3500 rack current draw up to 2.5 A maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBently Nevada 3500 Series Machinery Protection Systems\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery condition monitoring systems\u003c\/li\u003e\n\u003cli\u003eRedundant and primary power input distribution setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e129478-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh Voltage dc Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3500\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e88 to 140 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd\u003e2.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eFuse opens on over-voltage; under-voltage will not harm the PIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe power input module is a special half-height module located directly behind the associated power supply module on the left side of the rack. Mount the unit in the dedicated rear rack slot. Ensure proper fuse placement (replacement fuse part number 01720025) prior to applying power. No minimum rack load is required for operation.\u003c\/p\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2, EN 55011\/CISPR 11, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Community Directives:\u003c\/strong\u003e EMC Directive 2004\/108\/EC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety Standards:\u003c\/strong\u003e EN 61010-1, Low Voltage Directive 2006\/95\/EC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (North American Option 01):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eWith internal barriers: Ex nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2\/0, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003cli\u003eWithout internal barriers: Ex nC [L] IIC: Class I, Div 2; AEx nC IIC: Class 1, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals (ATEX Option 02):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eWith internal barriers: II 3\/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003cli\u003eWithout internal barriers: II 3\/(3) G, Ex nC[nL Gc] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrazil Approval (Option 02):\u003c\/strong\u003e BR-Ex nC [nL] IIC T4, T4 @ Ta = -20 degC to +65 degC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847592811,"sku":"129478-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-129478-01-high-dc-power-input-module-xx5cs5db2eg_b79155a2-f03c-4e2b-b4e1-7ef67da26e9a.jpg?v=1765448965","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-129478-01-high-voltage-dc-power-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}