{"product_id":"bently-nevada-133819-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-01 3500\/60 RTD\/TC Non-Isolated I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 133819-01\u003c\/strong\u003e is a rear-mount \u003cstrong\u003e3500\/60 RTD\/TC non-isolated I\/O module\u003c\/strong\u003e equipped with \u003cstrong\u003einternal terminations\u003c\/strong\u003e designed for the 3500 Series Machinery Protection System. It provides terminal connections for up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) signals, transferring conditioned temperature data to the main 3500\/60 monitor module. The \u003cstrong\u003e133819-01\u003c\/strong\u003e accepts mixed RTD and TC inputs across its six channels and utilizes direct internal screw\/header terminal blocks for field transducer wiring without requiring external termination blocks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts up to 6 RTD or Thermocouple transducer inputs with non-isolated signal conditioning.\u003c\/li\u003e\n\u003cli\u003eIntegrated internal terminal blocks for direct field wiring connection.\u003c\/li\u003e\n\u003cli\u003eSupports mixed configuration of RTD and TC sensor types across channels via rack configuration software.\u003c\/li\u003e\n\u003cli\u003eMounts directly into a single full-height rear slot of the 3500 rack system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery temperature monitoring for industrial rotating equipment\u003c\/li\u003e\n\u003cli\u003eBearing and winding temperature protection in power generation and petrochemical facilities\u003c\/li\u003e\n\u003cli\u003eContinuous asset health monitoring integrated into Bently Nevada 3500 Series TSI systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart \/ Option\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/60 RTD\/TC Non-Isolated I\/O Module, Internal Terminations, No Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/60 RTD\/TC Non-Isolated I\/O Module, Internal Terminations, CSA\/NRTL\/C Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/60-01-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/60 RTD\/TC Non-Isolated I\/O Module, Internal Terminations, ATEX\/IECEx\/CSA Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e133819-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare 3500\/60 RTD\/TC Non-Isolated I\/O Module with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Capabilities\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransducer Signal Inputs\u003c\/td\u003e\n\u003ctd\u003eAccepts 1 to 6 RTD or TC signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003e100 ohm 3-wire\/4-wire Pt (alpha = 0.00385 or 0.00392), 120 ohm 3-wire\/4-wire Ni, 10 ohm 3-wire\/4-wire Cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSupported TC Types\u003c\/td\u003e\n\u003ctd\u003eType E, Type J, Type K, Type T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 Mohm for each lead input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Space Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin \/ Header\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Terminal Strip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal input connections for RTD\/TC Channels 1 through 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Header 00580442\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-position internal termination green header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Header 00580443\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-position internal termination green header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Header 00580444\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-position internal termination green header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into the rear slot of the 3500 rack directly aligned behind the corresponding 3500\/60 main monitor module.\u003c\/li\u003e\n\u003cli\u003eSecure the card in place by tightening the top and bottom captive mounting screws.\u003c\/li\u003e\n\u003cli\u003eWire field RTD or thermocouple sensor leads directly to the green internal terminal connectors using appropriate field wiring guidelines.\u003c\/li\u003e\n\u003cli\u003eEnsure proper cable shielding to minimize electromagnetic interference on low-voltage thermocouple and resistance measurement circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive\u003c\/strong\u003e: 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Directive\u003c\/strong\u003e: 2014\/35\/EU (EN 61010-1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e: 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCyber Security\u003c\/strong\u003e: Designed to meet IEC 62443\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: SIL 2 rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Approvals\u003c\/strong\u003e: DNV GL rules, ABS rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e: CSA\/NRTL\/C (Class I, Div 2 \/ Zone 2), ATEX\/IECEx (Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666520174955,"sku":"133819-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133819-01-rtd-tc-temp-i-o-module-internal-termination-0agjwchdyju_12e8579b-0489-49e2-83f4-a0d5b2bd6141.jpg?v=1765440147","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-133819-01-3500-60-rtd-tc-non-isolated-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}