{"product_id":"bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133827-01 3500\/60 RTD\/TC Non-Isolated I\/O  Module","description":"\u003ch3\u003eCore Product Insights\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(133827-01) functions as a high-reliability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTD\/TC Non-Isolated I\/O Module designed for External Terminations. This module interfaces directly with external terminal blocks to process critical temperature inputs from Resistance Temperature Detectors (RTDs) and Thermocouples (TCs). In heavy industries such as petrochemical refining, LNG processing, and power generation, thermal anomalies indicate impending machinery failure. By delivering continuous, high-precision thermal monitoring to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this component prevents catastrophic failures, eliminates false trips, and significantly reduces un-scheduled industrial downtime.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture \u0026amp; Interface Options\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is engineered for high-density signal processing within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack backplane. It serves as the physical link between field-mounted temperature sensors and the main\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor card. The external termination architecture allows engineers to route field wiring to a separate termination block located outside the main rack enclosure. This setup simplifies high-density cabinet wiring, facilitates rapid maintenance, and improves cable management. The non-isolated circuit design relies on correct system-level grounding and external premium shielding to maintain signal integrity across long-distance industrial sensor runs.\u003c\/p\u003e\n\u003ch3\u003eCrucial Data Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\u003c\/strong\u003e Series Machinery Protection System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTD\/TC Non-Isolated I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e244 mm x 23 mm x 112 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Input Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlatinum RTD, Copper RTD, Nickel RTD, Type E\/J\/K\/T\/S\/R Thermocouples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 133827-01 handle signal noise given its non-isolated design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module relies on high-quality external shielded twisted pair cabling and a single-point industrial ground network. Engineers must ensure proper shield termination at the external block to mitigate common-mode noise interferences.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary advantage of selecting external terminations over internal ones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExternal terminations allow maintenance personnel to replace the I\/O module without disconnecting any field wiring. This layout drastically minimizes human wiring errors during field replacement procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module mix RTD and Thermocouple inputs on the same card simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitor software allows independent channel configuration. You can program specific channels for RTDs and others for Thermocouples on the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133827-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Deployment \u0026amp; Wiring Engineering Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGround all sensor wire shields strictly at the external termination block. Do not ground the shield at the sensor end in the field. This prevents dangerous ground loops from corrupting the micro-volt signals of the thermocouples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen fastening the I\/O module to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis rear rails, tighten the retaining chassis screws to exactly\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 N m\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof torque to prevent backplane connector strain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Routing Guidelines:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the external termination cables are routed away from high-voltage AC motor lines or variable frequency drives (VFD) to protect the non-isolated circuitry from electromagnetic cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861289835,"sku":"133827-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-133827-01-pc-board-plc-add-on-board-taordovzb0n_6f56e6e5-a692-4318-9449-b1d0067d7924.jpg?v=1765449309","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-133827-01-3500-60-rtd-tc-non-isolated-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}