{"product_id":"bently-nevada-134652-01-tdxnet-cpu-processor-board","title":"Bently Nevada 134652-01 TDXnet CPU Processor Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e134652-01\u003c\/strong\u003e is a CPU Processor Board designed to provide the processing interface between compatible machinery protection systems and Bently Nevada on-line machinery management software. The \u003cstrong\u003e134652-01\u003c\/strong\u003e continuously collects steady-state and startup\/shutdown transient data in parallel from connected monitoring channels. Operating within the TDXnet communications processor, the board manages data collection, processes 4 Keyphasor input channels, and routes processed static, orbit, and spectrum data to host systems over Ethernet (IEEE 802.3 TCP\/IP) or RS485 serial multidrop SDI links.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eImmediate recovery from power loss\u003c\/li\u003e\n\u003cli\u003eHigh-resolution static, orbit, and spectrum data acquisition\u003c\/li\u003e\n\u003cli\u003eEthernet link to Data Manager 2000 host computers\u003c\/li\u003e\n\u003cli\u003eTwo independent startup\/shutdown data buffers and one independent delta-time buffer\u003c\/li\u003e\n\u003cli\u003eParallel collection of steady-state and startup\/shutdown data\u003c\/li\u003e\n\u003cli\u003eKeyphasor-based startup and shutdown data acquisition eliminating external contact closures\u003c\/li\u003e\n\u003cli\u003eRS485 multidrop interface supporting Allen-Bradley and Modbus SDI protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOnline machinery condition monitoring and transient data acquisition\u003c\/li\u003e\n\u003cli\u003eReal-time startup and coastdown data processing for industrial rotating machinery\u003c\/li\u003e\n\u003cli\u003eSystem interface for Bently Nevada 3500, 3300, and 2201 Machinery Protection Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e134652-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTDXnet CPU Processor Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 per unit, 60 to 60,000 rpm range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbps, conforming to IEEE 802.3 (RJ-45 and 15-pin AUI connections)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP encapsulating Bently Nevada proprietary protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial SDI Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485 multidrop link supporting Allen-Bradley and Modbus protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Sampling Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC coupled, ±25 Volts input with up to 25 Volts peak-to-peak AC signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronous Waveform Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser configurable: 128 samples\/rev (8 revs), 64 samples\/rev (16 revs), 32 samples\/rev (32 revs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAsynchronous Waveform Sampling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 400-line Spectrum at 20 kHz frequency span (anti-alias filtered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent Startup\/Shutdown buffers, 1 independent Delta-Time buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 vector records and 32 waveform records per delta time\/RPM buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+90 to +240 Vac, 50 to 60 Hz; 89 Watts maximum power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ-45 \/ 15-pin AUI\u003c\/td\u003e\n\u003ctd\u003eEthernet 10Base-T \/ 10Base-2 network interface to host computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 SDI Port\u003c\/td\u003e\n\u003ctd\u003eSerial Distributed Interface link for DCS\/Modbus\/Allen-Bradley communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic \/ Static Connectors\u003c\/td\u003e\n\u003ctd\u003eConnection interfaces to monitoring system racks (3500, 3300, 2201)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyphasor Inputs\u003c\/td\u003e\n\u003ctd\u003eTerminal\/connector interface for 4 Keyphasor transducer signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the TDXnet enclosure is isolated from line power before installing or removing circuit boards.\u003c\/li\u003e\n\u003cli\u003eMount the CPU board securely inside the designated slot within the TDXnet communications processor assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain proper electrostatic discharge (ESD) precautions during handling; handle circuit assemblies by the edges or shield handles.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet cables and RS485 serial communication cabling away from high-voltage lines to minimize signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertificate 158809: EN50081-2 (EN55011 Class A Radiated\/Conducted Emissions), EN50082-2 (ENV50140, ENV50204, ENV50141, EN61000-4-2, EN61000-4-4, EN61000-4-8, EN61000-4-11)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Voltage Directives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertificate 158809: EN61010-1 Safety Requirements, EN61000-3-2:1995 Harmonic Content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCSA\/NRTL\/C Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption (01): Class 1, Division 2, Groups A, B, C, D; T4 @ Ta = 65 degC (Certification CSA 150368 \/ LR 26744)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852508011,"sku":"134652-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-134652-01-transient-data-interface-card-gbg00mtzmmz_e61454ba-70f2-492c-a47d-cfca8e26c851.jpg?v=1765449086","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-134652-01-tdxnet-cpu-processor-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}