{"product_id":"bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","title":"Bently Nevada 135473-01 3500\/25 Keyphasor I\/O Module (Internal Barriers)","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized half-height I\/O module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Keyphasor system. This specific configuration integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Barriers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e, providing a hardware-based intrinsic safety interface for transducers located in hazardous areas. The module is engineered to receive and process once-per-turn or multiple-per-turn pulse signals from proximity probes or magnetic pickups, which are essential for calculating machine rotative speed and providing a phase reference for vibration analysis.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the physical interface within the 3500 rack, ensuring electrical isolation and signal conditioning for critical machinery protection. While the module supports phase measurements, it is optimized for high-accuracy shaft speed monitoring. When utilizing the internal barrier version, the module provides a secure connection point that limits electrical energy dispatched to field sensors, complying with rigorous industrial safety standards for explosive atmospheres.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKeyphasor I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Barriers (Zener Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Transducer Signals (Proximity or Magnetic Pickup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 Watts typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.8 k ohm minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range (Non-Isolated)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+0.8 V to -21.0 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMagnetic Pickup Min Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 200 rpm (3.3 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.46 kg (1.01 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +65 deg C (32 deg F to +150 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eIndustrial procurement should focus on the specific part number to ensure compatibility with the 3500\/25 monitor configuration.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: Keyphasor I\/O Module with Internal Barriers and Internal Terminations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e: Original New\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvailability\u003c\/strong\u003e: Spare Part Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module provide isolation for Proximitor applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is compatible with Proximitor applications but requires an external power supply to provide isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary design intent of the Isolated I\/O version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt was created specifically for magnetic pickup applications where signals are tied in parallel to multiple devices, such as control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if input signals exceed the specified range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSignals exceeding the specified voltage range are limited internally by the module circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Reference: Wiring, Jumpers, and Specifications\u003c\/h3\u003e\n\u003ch3\u003e1. CHANNEL WIRING \u0026amp; PIN DEFINITIONS\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Internal Termination I\/O module with built-in Galvanic Barriers. It features two independent terminal strips for Channel 1 and Channel 2.\u003c\/p\u003e\n\u003ch4\u003eA. Proximity Probe Wiring (3-Wire)\u003c\/h4\u003e\n\u003cp\u003eFor standard eddy current sensors (e.g., 3300 XL series):\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR (-24V):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower output for the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM (GND):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignal common\/return.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG (OUT):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInput for the pulse voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Magnetic Pickup Wiring (Passive 2-Wire)\u003c\/h4\u003e\n\u003cp\u003eFor self-generating electromagnetic speed sensors:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect to sensor positive (+) lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCOM:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect to sensor negative (-) lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWR:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMust remain disconnected (Floating).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Shielding and IS Grounding\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSHLD (Shield):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect field cable shields to this dedicated terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIS Earth :\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module must be grounded via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01 Barrier Earth Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto a dedicated Intrinsic Safety ground bus to ensure explosion-proof integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. HARDWARE JUMPER CONFIGURATIONS\u003c\/h3\u003e\n\u003cp\u003eJumpers are located on the internal circuit board and must be set before installation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Power Jumper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Coupling Jumper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLogical Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProximity Probe\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eINT\u003c\/strong\u003e (Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC\u003c\/strong\u003e (Direct Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProvides power; allows DC bias.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMagnetic Pickup\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEXT\u003c\/strong\u003e (External\/OFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC\u003c\/strong\u003e (Alternating Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCuts power; filters DC noise.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways power down the 3500 rack or remove the Monitor Module before adjusting jumpers to avoid electrical arcing.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch3\u003e3. CORE PERFORMANCE SPECIFICATIONS\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 independent input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 to 1,200,000 cpm (\u003cstrong\u003e0.017 Hz to 20 kHz\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e+5V to -11V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(specifically for Barrier I\/O).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConditioning Modes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMin signal 2 V peak-to-peak; min speed 120 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManual Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdjustable from 0 to -20 Vdc; min signal 500 mV; supports low speed down to 1 rpm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.2 Watts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Typical).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 deg C to 65 deg C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. HAZARDOUS AREA CERTIFICATIONS\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-risk environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNorth America:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Div 2, Groups A, B, C, D.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEurope (ATEX):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eII 1 G [EEx ia] IIC (Inputs rated for Zone 0).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e5. SYSTEM CONFIGURATION SUPPORT\u003c\/h3\u003e\n\u003cp\u003eAfter the physical installation, use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto verify:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHysteresis Settings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent false triggering on noisy signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSetting the pulse direction (Positive\/Negative).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring the software matches the physical jumper settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003ePART 2: TERMINAL DIAGRAMS \u0026amp; SOFTWARE CONFIGURATION\u003c\/h3\u003e\n\u003ch3\u003e1. TERMINAL BLOCK PINOUT (A\/B\/C\/D)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e135473-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a specific 4-terminal sequence for each channel. Below is the mapping for connecting your field wiring:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLabel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProximity Probe (3-Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMagnetic Pickup (2-Wire)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePWR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-24 Vdc Power (White)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNO CONNECTION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCOM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommon\/GND (Black)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Negative (-)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSIG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Input (Red)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Positive (+)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSHLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShield\/Drain Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShield\/Drain Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. SOFTWARE CONFIGURATION (3500 RACK CONFIG)\u003c\/h3\u003e\n\u003cp\u003eOnce the hardware is installed, you must configure the following in the software utility:\u003c\/p\u003e\n\u003ch4\u003eA. Threshold Settings\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Threshold\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system automatically calculates the trigger point at 50% of the signal amplitude.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e: Standard operating speeds (\u0026gt;120 rpm) with clean, consistent pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManual Threshold\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYou manually set a fixed voltage (e.g., -8.0 Vdc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBest for\u003c\/strong\u003e: Low-speed start-ups or signals with significant \"glitch\" or noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalculation Tip\u003c\/strong\u003e: Set the threshold to the midpoint between the pulse peak and the baseline signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eB. Hysteresis (Noise Reduction)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMagnetic Pickups\u003c\/strong\u003e, you should set a Hysteresis value (typically\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.2V to 0.5V\u003c\/strong\u003e) to prevent the monitor from \"double-triggering\" if the signal is noisy as it crosses the threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eC. Active Edge (Direction)\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNegative Edge\u003c\/strong\u003e: Triggers as the signal goes from 0V toward -24V (Standard for most Bently probes).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePositive Edge\u003c\/strong\u003e: Triggers as the signal moves in a positive direction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e3. CRITICAL INSTALLATION CHECKLIST\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBarrier Earth\u003c\/strong\u003e: Ensure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e136719-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is installed in the rack. Without this, the 135473-01 cannot properly ground the internal safety barriers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Audit\u003c\/strong\u003e: Double-check that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChannel 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ejumpers match their respective sensors. A common error is leaving the PWR jumper on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen using a Magnetic Pickup, which can induce noise or heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoding\u003c\/strong\u003e: Use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeg C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCelsius\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein your technical documentation to avoid the corrupted character issues previously encountered in your CMS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666847134059,"sku":"135473-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-135473-01-motion-controller-module-with-316l-stainless-steel-case-material-ag55zssqu3e_fe8b3db7-fd2e-41ca-ad85-8851d4d47e88.jpg?v=1765448946","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-135473-01-3500-25-keyphasor-i-o-module-internal-barriers","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}